Lincoln Electric 11672 Operator's Manual page 31

Hide thumbs Also See for 11672:
Table of Contents

Advertisement

B-10
NON-SYNERGIC GMAW AND FCAW
WELDING
In non-synergic modes, the WFS control is similar to a
conventional CV power source where WFS and volt-
age are independent adjustments. Therefore to main-
tain the arc characteristics, the operator must adjust
the voltage to compensate for any changes made to
the WFS.
WFS
300
AMPS
+
MORE
LESS
WFS
WFS
WELD MODE
PROCESS
GMAW, STANDARD CV
GMAW, POWER MODE
FCAW, STANDARD CV
UltimArc™ Control
EFFECT / RANGE
PINCH
Pinch controls the arc characte-
(Soft)-10.0 to
-ristics when short-arc welding.
(Crisp)+10.
0
OPERATION
BASIC OPERATION
MODES 5 AND 6
25.3
VOLTS
TRIM
+
LESS
MORE
VOLTS
VOLTS
CONTROL OPTIONS
WELD MODE
5
40
6
5
STD CV MIG
WELD MODE
UltimArc™ Control
DESCRIPTION
POWER WAVE
UltimArc™Control, adjusts the apparent inductance of
the wave shape. The UltimArc™Control adjustment is
similar to the "pinch" function in that it is inversely pro-
portional to inductance. Therefore, increasing
UltimArc™Control greater than 0.0 results in a crisper
arc
(more
spatter)
UltimArc™Control to less than 0.0 provides a softer
arc (less spatter).
MODE 40
WFS
250
AMPS
+
MORE
LESS
LESS
WFS
VOLTS
WFS
START OPTIONS
EFFECT
Preflow Time
Adjusts the time that shielding gas
flows after the trigger is pulled
and prior to feeding wire.
Run-In WFS:
Run-In sets the wire feed
.
speed from the time the trigger
is pulled until an arc is estab-
lished.
Start Procedure
The Start Procedure controls
the WFS and Volts for a speci-
fied time at the beginning of
the weld. During the start time,
the machine will ramp up or
down from the Start Procedure
to
Procedure.
SETUP
START OPTIONS
END OPTIONS
END OPTIONS
EFFECT
Spot Timer
Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.
Crater Procedure controls the
Crater Procedure
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
The burnback time is the
Burnback:
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Postflow Time
Adjusts the time that shielding
gas flows after the welding out-
put turns off.
C300
®
B-10
while
decreasing
the
54
VOLTS
TRIM
+
MORE
VOLTS
DESCRIPTION
the
preset
Welding
DESCRIPTION

Advertisement