This document explains how to connect to the NI 9207. In this document, the NI 9207 with spring terminal and the NI 9207 with DSUB are referred to inclusively as the NI 9207. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation.
Page 5
NI 9207 with DSUB Safety Voltages Connect only voltages that are within the following limits: Isolation Channel-to-channel None Channel-to-earth ground Continuous 60 VDC, Measurement Category I Withstand up to 1,000 Vrms, verified by a 5 s 2,000 m dielectric withstand test Withstand up to 500 Vrms, verified by a 5 s 5,000 m...
Page 7
Do not remove modules unless power has Caution been switched off or the area is known to be nonhazardous. Substitution of components may impair Caution suitability for Class I, Division 2. For Division 2 and Zone 2 applications, Caution install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15.
Page 9
Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. To ensure the specified EMC performance,...
Preparing the Environment Ensure that the environment in which you are using the NI 9207 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing Pollution Degree Maximum altitude 5,000 m...
Page 13
Table 1. Signal Descriptions Signal Description Positive analog input voltage connection Negative analog input signal connection Analog input current connection Vsup Voltage supply connection Common reference connection to isolated ground 12 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
Single-Ended Connections AI0+ – AI0– Voltage Source NI 9207 Connecting an External Power Supply You must connect an external power supply with a 0 to 30 V voltage range to the NI 9207. This power supply provides the current for the devices you connect to the module. You can connect only one external voltage supply to the NI 9207.
Connecting a Three-Wire Current Transducer External Power Supply Three-Wire Current – Transducer NI 9207 16 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you use the NI 9940 backshell kit to protect connections to the NI 9207 with spring terminal. Overvoltage Protection The NI 9207 provides overvoltage protection for each channel.
Where to Go Next CompactRIO NI CompactDAQ NI 9207 Datasheet NI 9207 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software 18 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ...