  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments NI 9940 at our website:...
  • Page 2 GETTING STARTED GUIDE NI 9207 16 AI, ±20 mA/±10 V, 24 Bit, 500 S/s Aggregate hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 3: Safety Guidelines

    This document explains how to connect to the NI 9207. In this document, the NI 9207 with spring terminal and the NI 9207 with DSUB are referred to inclusively as the NI 9207. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation.
  • Page 4 Do not connect the NI 9207 to signals or use Caution for measurements within Measurement Categories III or IV. NI 9207 Getting Started Guide | © National Instruments | 3 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 5 NI 9207 with DSUB Safety Voltages Connect only voltages that are within the following limits: Isolation Channel-to-channel None Channel-to-earth ground Continuous 60 VDC, Measurement Category I Withstand up to 1,000 Vrms, verified by a 5 s 2,000 m dielectric withstand test Withstand up to 500 Vrms, verified by a 5 s 5,000 m...
  • Page 6: Safety Guidelines For Hazardous Locations

    Do not disconnect I/O-side wires or Caution connectors unless power has been switched off or the area is known to be nonhazardous. NI 9207 Getting Started Guide | © National Instruments | 5 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 7 Do not remove modules unless power has Caution been switched off or the area is known to be nonhazardous. Substitution of components may impair Caution suitability for Class I, Division 2. For Division 2 and Zone 2 applications, Caution install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15.
  • Page 8: Electromagnetic Compatibility Guidelines

    NI 9207 Getting Started Guide | © National Instruments | 7 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 9 Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. To ensure the specified EMC performance,...
  • Page 10: Special Conditions For Marine Applications

    EMC performance is attained. NI 9207 Getting Started Guide | © National Instruments | 9 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 11: Preparing The Environment

    Preparing the Environment Ensure that the environment in which you are using the NI 9207 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing Pollution Degree Maximum altitude 5,000 m...
  • Page 12 AI12 AI13 Vsup Vsup AI13 AI14 Vsup Vsup AI14 Vsup AI15 Vsup AI15 Vsup Vsup Vsup Vsup NI 9207 Getting Started Guide | © National Instruments | 11 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 13 Table 1. Signal Descriptions Signal Description Positive analog input voltage connection Negative analog input signal connection Analog input current connection Vsup Voltage supply connection Common reference connection to isolated ground 12 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 14: Floating Differential Connections

    – AI0– Source 1 MΩ Resistor NI 9207 Grounded Connections AI0+ – AI0– Voltage Source NI 9207 NI 9207 Getting Started Guide | © National Instruments | 13 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 15: Single-Ended Connections

    Single-Ended Connections AI0+ – AI0– Voltage Source NI 9207 Connecting an External Power Supply You must connect an external power supply with a 0 to 30 V voltage range to the NI 9207. This power supply provides the current for the devices you connect to the module. You can connect only one external voltage supply to the NI 9207.
  • Page 16: Connecting A Loop-Powered Current Transducer

    Connecting a Loop-Powered Current Transducer External Power Supply – Loop-Powered Current Transducer NI 9207 NI 9207 Getting Started Guide | © National Instruments | 15 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 17: Connecting A Three-Wire Current Transducer

    Connecting a Three-Wire Current Transducer External Power Supply Three-Wire Current – Transducer NI 9207 16 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 18: High-Vibration Application Connections

    High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you use the NI 9940 backshell kit to protect connections to the NI 9207 with spring terminal. Overvoltage Protection The NI 9207 provides overvoltage protection for each channel.
  • Page 19: Where To Go Next

    Where to Go Next CompactRIO NI CompactDAQ NI 9207 Datasheet NI 9207 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software 18 | ni.com | NI 9207 Getting Started Guide hnology Group - Quality Instrumentation ...
  • Page 20: Worldwide Support And Services

    If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9207 Getting Started Guide | © National Instruments | 19 hnology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www...
  • Page 21 U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2009—2016 National Instruments. All rights reserved. 375206D-01 Sep16...