Bosch Worcester Greenstar Danesmoor 12/18 Installation, Commissioning And Servicing Instruction Manual page 17

Floor standing oil-fired condensing boiler conventional flue & room sealed flue
Hide thumbs Also See for Worcester Greenstar Danesmoor 12/18:
Table of Contents

Advertisement

1, 2
A
Directly below an opening, air brick, opening window etc.
1, 2
B
Horizontally to an opening, air brick, opening window, etc.
C
Below a plastic/painted gutter, drainage pipe or eaves if combustible material is protected
3
D
Below a plastic/painted gutter, drainage pipe or eaves without protection to combustible material
E
From vertical sanitary pipework
F
From an external or internal corner or from a surface or boundary alongside a terminal
G
Above ground or balcony level
H
From a surface or boundary facing a terminal
J
From a terminal facing a terminal
K
Vertically from terminal on the same wall
L
Horizontally from a terminal on the same wall
M
Above the point of highest intersection with the roof
N
From a vertical structure on the side of the terminal
O
Above a vertical structure less than 750mm from the side of a terminal
P
From a ridge terminal to a vertical structure on the roof
Q
Above or the side of any opening on a flat or sloping roof
R
Below any opening on a sloping roof
[N/A]
Not allowed
[CF]
Conventional flue
[RS(H)]
Room sealed (horizontal)
[RS(V)]
Room sealed (vertical)
[*]
Minimum distance of the flue terminal from above ground is
2100mm where directed to a public footpath, private access
route or a frequently used area and 2500mm from a car
parking area.
[**]
Recommended minimum distance of the flue terminal to a
facing wall, fence, building or property boundary is
2500mm.
1. Terminals should be positioned so as to avoid products of
combustion accumulating in stagnant pockets around the building or
entering into buildings.
2. Vertical structure in N, O and P includes tank or lift rooms, parapets,
dormers etc.
3. Terminating positions should be at least 1.8m from an oil storage
tank unless a wall with at least 30 minutes fire resistance and
extending 300mm higher and wider than the tank is provided
between the tank and the terminating position.
Danesmoor Kitchen and Kitchen System 6 720 808218 (2013/10)
Terminal position
boundary
F
J
H
boundary
• Where a flue is terminated less than 600mm away from a projection
above it and the projection consists of plastics or has a combustible
or painted surface, then a heat shield of at least 750mm wide should
be fitted.
• If the lowest part of the terminal is less than 2m above the ground,
balcony, flat roof or other place to which any person has access, the
terminal should be protected by a guard.
• Notwithstanding the dimensions given above, a terminal should not
be sited closer than 300mm to combustible material. In the case of a
thatched roof, double this separation distance should be provided. It
is also advisable to treat the thatch with a fire retardant material and
close wire in the vicinity of the flue.
• It is essential that a flue or chimney does not pass through the roof
within the shaded area delineated by dimensions Q and R.
• Where protection is provided for plastic components, such as
guttering, it is essential that this is to the standard specified by the
manufacturer of the plastic components.
P
Q
Q
Q
M
R
Pitched roof
C, D
B
A
E
G
6720808218-19.1Wo
Pre-Installation
CF
RS(H)
RS(V)
N/A
600mm
N/A
N/A
600mm
N/A
N/A
75mm
N/A
N/A
600mm
N/A
N/A
300mm
N/A
N/A
300mm
N/A
N/A
300mm*
N/A
N/A
600mm**
N/A
---
1200mm**
N/A
1500mm
N/A
---
750mm
600mm
----
600mm
750mm
---
750mm
600mm
---
600mm
1500mm
---
N/A
300mm
---
300mm
1000mm
---
1000mm
O
Q
Q
Q
Q
Flat roof
N
K
F
F
L
----
---
17