PHCC S2033 Instruction Manual & Safety Warnings

PHCC S2033 Instruction Manual & Safety Warnings

Sump pumps

Advertisement

Quick Links

Sump Pumps
Instruction Manual &
Safety Warnings
Models S2033 & 2050

Items Included:

Pump
Choice of controller, float
Stainless steel hose clamp
You may also need:
1-1/2" rigid PVC pipe to
connect to the existing
plumbing
A check valve or union
PVC pipe cleaner and cement
Dual Float
Enhanced
Controller
Controller

Important Safety Instructions

SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING
INSTRUCTIONS. You will need to refer to it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property damage,
serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
!
WARNING
following precautions.
• ALWAYS disconnect the pump and float switch controller from the power source before servicing
or making adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp surface
while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is wired with
a 3-prong grounded plug. To reduce the risk of electric shock, be certain that it is only connected
to a properly grounded, 3-prong receptacle. If you have a 2-prong receptacle, have a licensed
electrician replace it with a 3-prong receptacle according to local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of the pump's
power cord, and at least 4 feet above the floor level to minimize potential hazards from flood
conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking
the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle the power
requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or property
!
CAUTION
damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT pull on the float switch cord.
• DO NOT expose the control unit to any type of moisture, water, rain or snow.
• DO NOT place the controller on the floor. The electrical outlet should be within the length of the
pump's power cord and at least 4 ft above the floor.
• DO NOT operate this product if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids. This pump
is for ground water only.
• DO NOT use in continuous duty applications such as fountains or ponds. This pump is rated for
intermittent use only.
• DO NOT disassemble this product. When service is required, contact Glentronics technical support
at 800-991-0466. Return the product to the manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
• When installing or replacing a primary sump pump you should also install a battery backup sump
pump system.

Specifications

1/3 HP Model S2033
GPH @ 0'
GPH @ 10'
Pump diameter
Volts
115V, 60Hz
Amps
Deluxe
Controller
1/2 HP Model S2050
4000
4300
3200
3600
8.5"
8.5"
115V, 60Hz
5.0
6.0
Dual Float
Vertical Float
Switch
Switch
Tether Float
Switch

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S2033 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PHCC S2033

  • Page 1 3-prong receptacle. If you have a 2-prong receptacle, have a licensed electrician replace it with a 3-prong receptacle according to local codes and ordinances. Models S2033 & 2050 • NEVER bypass grounding wires or remove the ground prong from the plug.
  • Page 2 (e) Lower the pump into the sump by the handle. NOTICES (f) Connect the pipe on the pump to the existing discharge pipe with a rubber union • When a check valve is used, a 1/8” (3.2mm) air bleed hole must be drilled in or check valve and tighten the hose clamps securely.
  • Page 3 Connecting the Pump and Controller Stop the pump and refer to the troubleshooting guide. The vertical and tether float switch must be moving freely at all times. Make sure the float switch does not Make sure the outlet is single phase, 115V and 60HZ come into contact with other pumps, wires, pipe or any other object that may be WARNING for all the pump installations.
  • Page 4 Maintenance Check List the homeowner to address the problem. If this warning light and alarm are on, the control box is not receiving AC power for one Maintenance should be performed 1-2 times per year. of many reasons: 1. Remove all debris from the bottom of the pit and make sure the 1.
  • Page 5 Troubleshooting (Always unplug the pump from the controller before performing any maintenance) Pump is not plugged in Plug pump in properly (see instructions) Water is not high enough to activate the pump Make sure float switch is positioned properly Open circuit Check circuit breaker or fuse Poor power source Check circuit line wires and cable*...
  • Page 6 Limited Warranty By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.