Download Print this page

Bauer HYPERMAX LITHIUM 2144C-B Owner's Manual & Safety Instructions page 9

1/2 gallon cordless chemical fogger
Hide thumbs Also See for HYPERMAX LITHIUM 2144C-B:

Advertisement

troubleshooting
problem
Tool will not start.
1. Battery Pack not properly
2. Battery Pack not properly
3. Battery Pack burnt-out.
4. Internal damage or wear. (Motor
Tool operates
1. Battery Pack wearing out.
slowly or shuts off.
2. Solution is too thick.
Performance
Motor worn or damaged.
decreases over time.
Excessive noise
Internal damage or wear. (Motor
or rattling.
or bearings, for example.)
Overheating.
Blocked motor housing vents.
Tank pressure is
1. Tank cap is not screwed tight.
not building.
2. O-ring in cap needs
Spray is weak.
1. Filter needs to be cleaned.
2. Solution is too thick.
Tool spurts or
The Fogger is tilted or being held at
streams liquid
an angle, and not being held level.
instead of fogging.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect Battery pack and charger power supply before service.
Item 59565
possible causes
connected.
charged.
or Trigger, for example.)
to be replaced.
For technical questions, please call 1-888-866-5797.
Likely Solutions
1. Remove Battery Pack, make sure there are no
obstructions, reinsert the Battery Pack according
to its shape (it should only fit one way), and press
firmly until the Battery Pack locks in place.
2. Make sure Charger is connected and
operating properly. Give enough time for
Battery Pack to recharge properly.
3. Dispose of old Battery Pack
properly or recycle. Replace Battery Pack.
4. Have technician service tool.
1. Dispose of old Battery Pack
properly or recycle. Replace Battery Pack.
2. Chemical / water solution must be as thin as water.
Have qualified technician replace motor.
Have technician service tool.
Wear ANSI-approved safety goggles and
NIOSH-approved dust mask/respirator while
blowing dust out of motor using compressed air.
1. Tighten tank cap.
2. Replace O-ring in cap.
1. Clean the filter as described in the Maintenance
and Servicing section of this manual.
2. Chemical / water solution must be as thin as water.
Hold the Fogger level.