Fujitsu AR G07LL A Series Service Instruction page 69

Split type room air conditioner slim duct / compact cassette compact wall mounted / floor type inverter multi
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 2
Inverter Compressor
Check Point 1 : Check Connection
Check terminal connection of Compressor
(loose or incorrect wiring)
Check Point 2 : Check Winding Resistance
Check winding resistance of each terminal
If the resistance value is 0
C
R
Check Point 3 : Replace Inverter PCB
If the symptom does not change with above Check 1, 2, replace Main PCB.
Terminal cover opened
C(T)
(BLACK)
S
R
(WHITE)
(RED)
or infinite, replace Compressor.
Resistance Value : 0.668
S
( at 25°C )
02-38

Advertisement

Table of Contents
loading

Table of Contents