11. 4-WAY VALVE EXTENSION SELECT

At the time when the air conditioner is switched from the Cooling mode to Heating mode,
the compressor is stopped, and the 4-way valve is switched in 3 minutes later
after the compressor stopped.

12. AUTO RESTART

When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically resumed with
the memorized operation contents.
(Table 8 : Operation contents memorized when the power is interrupted)
Operation mode
Set temperature
Set air flow
Thermistor detected position
Timer mode
*It is necessary to set on the DIP-SW1-No,6 of the wired remote controller, to enable the memory backup.
Refer to the installation manual of wired remote controller for details.

13. MANUAL AUTO OPERATION

If MANUAL / AUTO Button is pushed continuous from 3 seconds to 10 seconds,
manual auto operation will starts.
If the remote control is lost or battery power dissipated, this function will work without the remote
control.
(Table 9 : Manual auto operation control)
Functions
OPERATION MODE
SETTING TEMP.
FAN MODE
VERTICAL LOUVER
HORIZONTAL LOUVER
TIMER MODE
SWING OPERATION
ECONOMY
Wireless remote controller
All models
Auto changeover
24°C
Auto
NORMAL
NORMAL
Continuous
(No timer setting available)
OFF
OFF
Wired remote controller
(When Memory Backup : Disable)
01-19
Wired remote controller
(When Memory Backup : Enable)
OFF Timer
ON Timer
WEEKLY Timer
TEMPERATURE
SET BACK Timer
: Memorize
: Not memorize