Troubleshooting - EINHELL TE-IG 3500 Original Operating Instructions

Power generator
Hide thumbs Also See for TE-IG 3500:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18

10. Troubleshooting

Fault
Engine does not
start
Generator has too
little or no
voltage
The battery does
not charge up
Starter does not
turn
Anl_TE_IG_3500_SPK13.indb 25
Anl_TE_IG_3500_SPK13.indb 25
GB
Mögliche Ursache
Automatic oil cut-out has not respon-
ded
Spark plug fouled
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air fi lter dirty
Poor contact to the battery
Battery defective
12 V safety trip has been triggered.
Battery discharged
Battery not connected
- 25 -
Behebung
Check oil level, top up engine oil
Clean or replace spark plug (electro-
de spacing 0.7-0.8 mm)
Refuel / have the petrol cock checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the fi lter
Clean the contacts
Have the battery checked by an ex-
pert and replace it if necessary
Check the function of the equipment
using a diff erent battery; Actuate the
12 V safety trip.
Charge the battery
Connect the battery
22.06.2022 08:42:25
22.06.2022 08:42:25

Advertisement

Table of Contents
loading

This manual is also suitable for:

41.526.20

Table of Contents