  • Page 1 MT-16 airbag laminating& defoaming machine User Manual 1.safety rules-------------------------------- 2.Specifications------------------------------ 3.Steps for usage ----------------------------- 4.devices care--------------------------------...
  • Page 2: Safety Rules

    1. Safety Rules For your personal safety, read this manual carefully. Familiar with the application and limitations of the machine, as well as the potential hazards associated with the machine. A. Please read the instructions carefully before using the device. B.
  • Page 3 2. Press Parameter Setting to set device parameters.
  • Page 4 3. The factory default parameters are temperature: 40°C, vacuum time: 45 seconds, bonding time: 45 seconds, and defoaming time: 10 minutes. *No special requirements, please do not adjust the parameters without authorization, if you need to change the parameters, please contact the manufacturer after sales.
  • Page 5 2. Put the positioned screen into the special silicone pad for pressing the screen, put the glass panel down, then put it into the fitting cabin of the machine, and close the fitting door. *The placement of the screen is very important, which directly affects the final yield. The edge of the display window of the screen should be aligned with the edge of the sponge pad, so as to completely avoid the cable.
  • Page 6 * Different regions have different altitudes, which will affect the effect of vacuuming. The higher the altitude, the lower the peak value of negative pressure, and the best effect is when the negative pressure is above -88. ⑸Usually, the air in the cabin can be sucked out within 45 seconds of vacuum time, and then the airbag is slowly pressed down.
  • Page 7: Working Mode

    3. Take out the final product and check whether the display and touch are normal. *Before opening the hatch every time, check whether there is gas in the cavity. The checking method is to observe the positive and negative pressure values on the display screen.
  • Page 8 Press the start button, the device can start working, the positive pressure reaches 0.6MPA, and it runs until the defoaming time is set. When the device starts defoaming, when the set defoaming time is reached, the device starts to deflate, the positive pressure value returns to zero, and the defoaming is completed.
  • Page 9 defoaming mode, the positive pressure reaches 0.6MPA, and the device deflates when the set time is reached , the positive pressure gauge is reset to zero, the running time is reset to zero, and the fit and defoaming are completed. *The defoaming time can be adjusted according to the size of the bubbles on the screen, at least 5 to 10 minutes.