  • Page 1 YALOS RV TB/TN RV TB/TN RV TB/TN ISA S.r.l. Via del Lavoro, 5 06083 Bastia Umbra - Perugia - Italy Tel. +39 075 80171 - Fax +39 075 8000900 www.isaitaly.com YALOS USE AND MAINTENANCE MANUAL 428000585137...
  • Page 2: Table Of Contents

    MANUFACTURER WARRANTY TERMS AND CONDITIONS EQUIPMENT IDENTIFICATION COMPOSITION NOTES / IMPORTANT NOTES SAFETY SAFETY DEVICES PRESENT FIXED PROTECTIONS ISOLATING THE ELECTRIC POWER SUPPLY RESIDUAL RISKS RISKS OF CONTACT WITH LIVE PARTS FIRE EXPLOSIVE ATMOSPHERE SLIPPING TRIPPING 6.10 CIRCUIT FAULTS 6.11 WARNING SIGNS (if any) 6.12 RISKS OF EXPLOSION...
  • Page 3 Attachment 1 DECLARATION OF CONFORMITY Attachment 2 WIRING DIAGRAM - 412100605100 The manual contains symbols to attract the reader’s attention and highlight particularly important aspects. The table below illustrates the meaning of the various symbols used. Read the instructions manual Use of protective clothing Requests for maintenance or operations must Danger: Live electrical parts...
  • Page 4: Manufacturer

    1. MANUFACTURER ISA S.r.l. Via del Lavoro, 5 06083 - Bastia Umbra - Perugia - Italy Tel. +39 075 80171 Fax +39 075 8000900 www.isaitaly.com 2. WARRANTY TERMS AND CONDITIONS The seller's warranty on the equipment is valid for 12 (TWELVE) months from the date of delivery.
  • Page 5: Equipment Identification

    3. EQUIPMENT IDENTIFICATION • Find the label affi xed on the machine to read the technical data. • Check the machine model and the power supply voltage before you perform any operation. • If you uncover mismatches, contact the manufacturer or the company that supplied the machine immediately.
  • Page 6: Use

    4. USE This appliance is exclusively intended to: TB: EXPOSURE AND CONSERVATION OF ICE CREAM AND / OR FROZEN FOOD TN: EXPOSURE OF PRE-PACKAGED FRESH PRODUCTS The manufacturer is not liable for injury to persons or damage to property or the appliance itself caused by the displaying of products other than those described above.
  • Page 7: Notes / Important Notes

    Keep this manual in a safe place. It should be available for consultation near the equipment at all times. If lost or destroyed, you can request a copy of the manual from ISA S.r.l. by specifying the exact model, serial number and year of manufacture. The manual refl ects the manufacturing technology at the time of supply.
  • Page 8 INTRODUCTION ISA S.r.l. employs materials of the best quality and as they enter the company, we constantly monitor their storage and the use as part of the manufacturing process to prevent damage, deterioration and failure.
  • Page 9: Safety

    6. SAFETY The appliance is equipped with safety devices. 6.1 SAFETY DEVICES PRESENT Devices whose operation prevents the occurrence of risk situations in operating conditions (e.g. fuses, pressure switches, protections, magnet circuit breakers, etc.). 6.2 FIXED PROTECTIONS Fixed protective devices consist of fi xed perimeter shields, which are used to prevent external parts from entering the equipment.
  • Page 10: Fire

    6.6 FIRE Danger In the event of a fi re, immediately disconnect the master switch from the main power supply line. 6.7 EXPLOSIVE ATMOSPHERE The equipment must not be located in an area classifi ed as an explosion risk according to 1999/92/EC such as: Zone 0 An area in which there is a permanent, long-lasting or frequently explosive atmosphere made up of a...
  • Page 11: Refrigerants (Where Applicable)

    6.13 REFRIGERANTS (where applicable) REFRIGERANT DESCRIPTION The refrigerant R290 is a gas that is compatible with the environment, but highly fl ammable. Pay close attention during transport, installation and that the destruction not to damage the refrigerant pipelines. IN THE EVENT OF DAMAGE: Keep fl...
  • Page 12: Disposal Of Waste Material

    7. DISPOSAL OF WASTE MATERIAL During normal operation, the appliance does not generate any environmental contamination. At the end of its life cycle, or if it is necessary to proceed to permanent decommissioning, we recommend following the procedures below: DISPOSAL (User) The symbol, applied to either the product or its packaging, indicates that the product should not be considered as normal domestic waste, but should be taken to a waste collection point for the recycling of electrical and electronic appliances.
  • Page 13: Installation

    8. INSTALLATION This manual supplies the information necessary for correct unpacking, procedures for positioning and connection to mains electricity. 8.1 STORAGE AND UNPACKING The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the elements and direct sunlight, at a temperature between 0 and +40 °C. The appliance should only be moved by qualifi...
  • Page 14: Maintenance

    9. MAINTENANCE The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table below, calling the authorised Technical After-sales assistance when indicated. OPERATION FREQUENCY AUTHORISED PERSONNEL CLEANING THE EXTERNAL SURFACES CLEANING THE ACCESSIBLE INTERNAL PARTS (without the use of tools) CONTROL POWER SUPPLY CABLE, USER...
  • Page 15: Faults - Technical After-Sales Assistance

    If the control unit is set up especially for must R290 refrigerant, it must only be replaced with an original replacement from ISA. Replace the temperature probes only after checking which of the two is not operating effi ciently.
  • Page 16: Alarms List (Where Present)

    10.1 ALARMS LIST (where present) ALARM DESCRIPTION OUTPUTS AUTHORISED PERSONNEL Broken thermostat probe. • The alarm starts a few seconds after the probe breaks down; it stops a few Compressor output according to seconds after the probe starts working again properly. “COn”...
  • Page 17: Technical Specifications

    11. TECHNICAL SPECIFICATIONS RV TB/TN RV TB/TN RV TB/TN External dimensions (Lenght) 1500 2100 2500 External dimensions (Depth) 1040 External dimensions (Height) Refrigeration Ventilated Defrosting Hot Gas Climate class N° Environmental conditions °C / %RH 30 / 55 Product class L1 (TB) / M1 (TN) Safety class N°...
  • Page 18: Installation

    11.1 INSTALLATION Attention It is fundamental to respect the distances indicated (mm) for correct installation of the appliance. aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa...
  • Page 19: Open / Close Glass Sliding

    11.4 OPEN / CLOSE GLASS SLIDING Attention To open and close the compartment exhibition scroll horizontally slides without force and close them manually making sure they are completely closed; improper closure negatively affects performance of ‘equipment and on the’ excessive ice buildup on the inner walls. Attention It ‘absolutely forbidden to place weights on glass surfaces.
  • Page 20: Control Panel

    12. CONTROL PANEL START-UP Press the master switch network. Plug the appliance in at the socket supplied by the customer, ensuring that the plug is fi tted with an earth contact and that there are no multiple sockets connected to it; the device automatically starts. Attention The electronic control board is installed already programmed.
  • Page 21: User Interface

    12.1 USER INTERFACE KEYS Scrolls menu options Increases the values Activates manual defrosting DOWN Scrolls menu options Decreases the values Press to turn on the internal lighting STAND-BY (ESC) Goes back up one level with respect to current menu Confi rms parameter value Activates the Stand-by function SET (ENTER) Accesses the Set-point...
  • Page 22 12.1 USER INTERFACE 12.1.1 SET SETTING Press the SET (ENTER) button and release immediately. The “Set” label will appear. To view the Set point value, press the SET (ENTER) button again. The Set-point value will appear on the display. To change the Set point value, press the UP and DOWNbuttons within 15 seconds. To confi...
  • Page 23: Cleaning

    13. CLEANING EXTERNAL STAINLESS STEEL Only use warm water and non-aggressive detergents and then rinse and dry using a soft cloth. ACRYLIC OR POLYCARBONATE Wash with lukewarm water, using a soft cloth or a chamois cloth. Do not use detergents, alcohol, acetone or solvents. Do not use abrasive cloths or sponges.
  • Page 24 13. CLEANING DEFROST WATER COLLECTION TRAY Attenzione Clean based on use and as needed and in certain environmental conditions (e.g., high humidity, low environmental temperature, presence of dust, etc.) in order to avoid the incorrect and complete evaporation of the water and/or the presence of unpleasant odours.
  • Page 25: Prolonged Appliance Switch-Off

    14. PROLONGED APPLIANCE SWITCH-OFF • Remove the product contained in the cabinet and put it immediately in a relevant cold storage container in order to guarantee correct preservation. • Open the appliance and wait for it to reach room temperature and then clean it. •...
  • Page 26 Attachment 1 - DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY We: ISA S.r.l. Via del Lavoro, 5 - 06083 - Bastia Umbra (PG) declare under our own responsibility, that the product: YALOS Product: Serial number: ..To which this declaration refers, is in compliance with e following: MACHINERY SAFETY General electric safety Standard EN 60335-1/Ed.2002+Modifi...
  • Page 27 Attachment 2 - WIRING DIAGRAM - 412100605100 YALOS USE AND MAINTENANCE MANUAL 428000585137...