Electrical Requirements - Delta WHITEWATER DF Series Installation, Operation And Maintenance Manual

Aerobic residential wastewater treatment system
Table of Contents

Advertisement

SPECIFICATIONS
MODEL
COMPRESSOR
DF-50
Delta Model 60
AP60
Delta Model 80
AP80
DF-60
AT05
5100S
Delta Model 80
AP80
Delta Model 100
DF-75
5100S
5120S
AT05
Delta Model 100
Delta Model 120
DF-100
(1) 0823
(2) Delta Model 80
(2) AP80
DF-150
(3) 5100S
(1) 1023
(2) 5120S
(3) Delta Model 100
(2) DELTA MODEL 120
TREATMENT
A
PLANT
DF50
4' 11-3/16"
DF60
5' 7-3/4"
DF75
6' 0-1/2"
DF100A
5' 9-5/8"
DF150
8' 3-5/8"
Refer to treatment plant drawings, pages 18 and 19, on the above dimensions.
Note: For special cargo or container shipments 12 inches must be added to the diameters of all fiberglass units (due to the
fiberglass flange and lifting lugs).
Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com

ELECTRICAL REQUIREMENTS

MOTOR FULL
LOAD AMPS
1.75
1.75
2.1
2.1
4.6
2.71
2.1
2.1
2.71
2.71
2.8
4.6
2.71
2.8
(1) 10.4
(2) 2.1
(2) 2.1
(3) 2.71
(1) 10.4
(2) 2.8
(3) 2.71
(2) 2.8
B
C
4' 8-3/16"
6' 0"
5' 4"
6' 3"
5' 8-1/2"
6' 9"
5' 6"
8' 0"
8' 0"
8' 0"
MEASURED
OPERATING WATTS
63
115 volt – single phase
63
85
85
449
115 volt – single phase
110
85
85
110
110
115 volt – single phase
157
449
110
157
(1) 640
115 volt – single phase
(2) 85
(2) 85
(3)110
115 volt – single phase
(1) 850
(2)157
(3) 110
(2) 157
D
E
4' 5-9/16"
5' 0"
5' 1-1/2"
5' 9"
5' 6"
6' 2"
5' 3"
6' 0"
7' 9-1/2"
8' 6"
ELECTRICAL
REQUIREMENTS
F
G
10"
6' 6"
11-1/2"
6' 9"
11-1/2"
7' 3"
1' 0"
8' 6"
1' 3-3/4"
8' 6"
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Df50Df60Df75Df100aDf150

Table of Contents