Technical Data

Operating Data
Operating frequency ILR-RFID
Maximum transmission power
Compatibility
Standards/Certification
Communication Data Long-Range RFID (ILR, Beacon Technology)
Read range broadcast
Operation mode
Repetition rate (ping rate)
Data rate broadcast
Communication Data Inductive Loop (Marker)
Read range
Operating frequency
Operation mode
Electrical Data
Power supply
Configuration
Ping rate
Number of Bursts
Environmental Conditions
Operating temperature
Shock
Vibration
Mechanical Data
Dimensions
Casing
Mass
Protection class
Certifications
EMC
VISIBILITY DELIVERED.
868 MHz (EU) or 920 MHz (NA)
0.75mW (EU / NA)
i-PORT M 350, i-CARD CF-350
FCC Part 15 (US), ETSI EN 300 220 (EU)
Up to 150 m (490 feet) free air*
Transmits marker information in at regular intervals
0,5 – 300 seconds, adjustable in steps of 0,5 seconds
115.2 kbits/s
*The communication range depends on the antenna type, the antenna
cable runs and the environmental conditions.
Up to several meters
125 kHz (world-wide approved)
Receives marker ID number and transmits marker information several
times
Lithium battery (not replaceable)
Configurable from 0.5 to 300 seconds
in steps of 0.5 seconds
Configurable from 0 to 15
–30 to +70 °C (–22 to +158 °F)
50 G, 3 times acc. DIN IEC 68-2-27
several times onto concrete floor from 1 m height
3 G, 20 sine wave cycles, 5 to 150 Hz,
DIN IEC 68-2-6
5 G, noise 5 to 1.000 Hz, 30 minutes
DIN IEC 68-2-64
52 × 42 × 14mm (2.04 × 1.65 × 0.55 inches)
Plastics
40 g
IP 68
CE (EN 300 220-1, -3; ETSI EN 301 489-1, -3),
FCC Part 15 (US), Industry Canada
PAGE 20 OF 21