Page 1
Voorraadvat Storage tank Ballons de stockage ST 1500/2000/2500/3000 Installatie-, Gebruikers- en Servicehandleiding Installation, User and Service Manual Manuel d'installation, d'utilisation et d'entretien...
Page 2
Farnborough Hampshire 5500 AB Veldhoven www.aosmith.co.uk GU14 ONR UK The Netherlands A.O. Smith siège France A.O. Smith siège social Europe 14, allée Charles Pathé De Run 5305 T : 01 3975 5140 18000 Bourges Boîte postale 70 info@aosmith.nl France 5500 AB Veldhoven www.aosmith.fr...
Page 3
Inhoudsopgave / Table of contents / Table des matières Deze handleiding bestaat uit 3 talen. 1 - NL Handleiding ST 1500 t/m 3000 .................. 5 2 - EN Manual ST 1500 trough 3000 .................. 21 3 - FR Notice ST 1500 à 3000 ................... 37 This manual consists of 3 languages.
Page 5
A.O. Smith Water Products Company. A.O. Smith Water Products Company behoudt zich het recht voor de specificaties zoals vermeld in deze handleiding te wijzigen.
Page 6
Installatie-, Service- en Gebruikerslandleiding...
Technische specificaties 1.1 Vloerbelasting Houd in verband met het gewicht van het toestel rekening met de maximale vloerbelasting, zie de tabel (1.6 "Algemene gegevens"). 1.2 Watersamenstelling Het toestel is bedoeld om drinkwater op te warmen. Het drinkwater moet voldoen aan de regelgeving voor drinkwater voor menselijke consumptie.
Installatie Belangrijk Bij deze toestellen worden de 3 anodes los meegeleverd. Monteer de anodes, met een vloeibaar afdichtingmiddel, in de juiste aansluitingen (8). Wanneer de anodes, tijdens in bedrijfsname, niet gemonteerd zijn vervallen alle garantievoorwaarden. 2.1 Aansluitschema De figuur geeft het aansluitschema weer. Dit schema wordt gebruikt in de paragrafen waarin het eigenlijke aansluiten wordt beschreven.
Page 14
Let op Een inlaatcombinatie is verplicht. Monteer deze zo dicht mogelijk bij het toestel. Waarschuwing Tussen inlaatcombinatie en het toestel mag nooit een afsluiter of terugslagklep geplaatst worden. 2.2.2 Warmwaterzijdig Zie (B) in het aansluitschema (2.1 "Aansluitschema"). Opmerking Isolatie van lange warmwaterleidingen voorkomt onnodig energieverlies. 1.
Vullen en aftappen Belangrijk Bij deze toestellen worden de 3 anodes los meegeleverd. Monteer de anodes, met een vloeibaar afdichtingmiddel, in de juiste aansluitingen (8). Wanneer de anodes, tijdens in bedrijfsname, niet gemonteerd zijn vervallen alle garantievoorwaarden. Installatie Schema Legenda 2.
3.2 Aftappen Sluit de afsluiter in de warmwaterleiding. Sluit de toevoerkraan van de inlaatcombinatie (2). Open de aftapkraan. Belucht het toestel (of installatie) zodat het helemaal kan leeglopen. Installatie-, Service- en Gebruikerslandleiding...
Onderhoud Let op Onderhoud mag alleen door een erkend service- en onderhoudsmonteur worden uitgevoerd. Bij elke onderhoudsbeurt dient het voorraadvat waterzijdig onderhouden te worden. Het onderhoud dient in de volgende volgorde te worden uitgevoerd. 1. Onderhoud voorbereiden 2. Waterzijdig onderhoud 3.
Page 18
Werkvolgorde: 1. Draai de bouten van de reiningsopening los. 2. Verwijder de deksel en de pakking. 3. Inspecteer de tank en verwijder de losse kalkaanslag en verontreinigingen. 4. Indien de kalkaanslag niet handmatig verwijderd kan worden, dient ontkalkt te worden met een ontkalkingmiddel. Neem contact op met de leverancier/fabrikant voor een advies over het te gebruiken ontkalkingmiddel.
Indien binnen één jaar na de oorspronkelijke installatiedatum van een door A.O. Smith geleverd voorraadvat, na onderzoek en ter uitsluitende beoordeling van A.O. Smith, blijkt dat een deel of onderdeel, met uitzondering van de tank, niet of niet juist functioneert ten gevolge van fabricage- en/of materiaalfouten, zal A.O. Smith dit deel of onderdeel vervangen of repareren.
5.5 Omvang garantie De verplichtingen van A.O. Smith krachtens de gegeven garantie gaat niet verder dan kosteloze levering af magazijn van de te vervangen delen of onderdelen respectievelijk voorraadvat. vervoers-, arbeids-, installatie- en andere met de vervanging verband houdende kosten komen niet voor rekening van A.O.
Page 21
Any brand names mentioned in this manual are registered trademarks of their Trademarks respective owners. A.O. Smith Water Products Company accepts no liability for claims from third parties Liability arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
Page 23
Water-side maintenance ..................33 Warranty ........................ 35 General warranty ....................35 Tank warranty ......................35 Conditions for installation and use ................35 Exclusions ....................... 36 Scope of warranty ....................36 Claims ........................36 Obligations of A.O. Smith ..................36 0312732_ST_1500-3000_NLENFR_V2.0, 2019-03-08...
Technical specifications 1.1 Floor load Allow for the storage tank's weight and the maximum floor load; refer to the table (1.6 "General specifications"). 1.2 Water composition The storage tank is intended for heating drinking water. The drinking water must comply with the regulations governing drinking water for human consumption. The table gives an overview of the specifications.
1.6 General specifications General specifications Unit ST 1500 ST 2000 ST 2500 ST 3000 Contents litres 1550 1880 2500 2820 Empty weight Maximum floor load 1875 2230 2985 3340 Energy Efficiency Class (Energy Label) Heat Loss Max. operating pressure tank kPa (bar) 700 (7) 700 (7)
Page 27
Front view of the appliance IMD-1301 R0.0 0312732_ST_1500-3000_NLENFR_V2.0, 2019-03-08...
These products can be installed as vented and unvented. This manual only discusses unvented installations. For information about vented installations please contact A.O. Smith. 2.1 Installation diagram This figure shows the installation diagram. This diagram is referred to in the sections describing the actual connection procedure.
Page 30
2.2.1 Cold water side See (A) in the installation diagram (2.1 "Installation diagram"). 1. Fit an approved stop valve (4) on the cold water side as required by the applicable regulations. 2. The maximum working pressure of the storage tank is 8 bar. Because the pressure in the water pipe at times can exceed 8 bar, you must fit an approved pressure-reducing valve (1).
Filling and draining Note These products can be installed as vented and unvented. This manual only discusses unvented installations. For information about vented installations please contact A.O. Smith. Installation Diagram Legend 1. pressure relief valve (mandatory if mains water pressure is too high) 3.
3.2 Draining 1. Close the stop valve (4) between the cold water head tank and the cold water inlet (A). 2. Open the drain valve (9). 3. Bleed the water heater (or installation) so that it drains completely. Installation, Service and User Manual...
Maintenance Warning Maintenance may only be carried out by a competent person. At each service, the storage tank undergoes maintenance on water side. The maintenance must be carried out in the following order. 1. Preparation for maintenance 2. Water-side maintenance 3.
Page 34
Work order: 1. Undo bolts from the cover. 2. Remove cover and the gasket. 3. Inspect the tank and remove the loose scale deposits and contamination. 4. If the scale cannot be removed by hand, descale the storage tank with a descaling agent.
A.O. Smith shall offer to replace the defective storage tank with an entirely new storage tank of equivalent size and quality The warranty period given on the replacement storage tank shall be equal to the remaining warranty period of the original storage tank that was supplied.
A.O. Smith Water Products Company products. Inspection of the storage tank as referred to in articles 1 and 2 shall take place in one of the laboratories of A.O. Smith. 5.7 Obligations of A.O.
Page 37
Aucune partie de ce document ne peut être copiée, dupliquée et/ou diffusée par impression, photocopie ou tout autre moyen de reproduction, sans l'accord écrit préalable de A.O. Smith Water Products Company. A.O. Smith Water Products Company se réserve le droit de modifier les spécifications de ce manuel d'instructions. Marques de commerce Toutes les marques mentionnées dans ce manuel d'instructions sont des marques...
Page 39
Entretien côté eau ....................47 Garantie ......................... 49 Garantie générale ....................49 Garantie sur la cuve ....................49 Conditions d'installation et d'utilisation ..............49 Exclusions ....................... 50 Portée de la garantie ....................50 Réclamations ......................50 Obligations de A.O. Smith ..................50 0312732_ST_1500-3000_NLENFR_V2.0, 2019-03-08...
Spécifications techniques 1.1 Charge maximale au Tenez compte de la charge maximale exercée sur le sol par le poids de l'appareil, sol de l'appareil voir le tableau (1.6 "Données générales"). 1.2 Composition de l'eau L'appareil est destiné à réchauffer de l'eau potable. L'eau potable doit être conforme aux régulations d'eau potable pour la consommation humaine.
1.6 Données générales Données générales Unité ST 1500 ST 2000 ST 2500 ST 3000 Capacité 1550 1880 2500 2820 Poids à vide Class Efficacité Énergétique (Étiquette d’Énergie) Consommation d’entretien Charge maximale au sol de l'appareil 1875 2230 2984 3340 Pres. de fonctionnement max. du cuve kPa (bar) 700 (7) 700 (7)
Page 43
Vue de frontale des appareils IMD-1301 R0.0 0312732_ST_1500-3000_NLENFR_V2.0, 2019-03-08...
Installation Important Dans ces appareils, les 3 anodes sont livrées séparément. Montez les anodes, avec un liquide d’étanchéité liquide, dans les raccordements corrects (10). Quand les anodes ne sont pas montées lors de la mise en service, les conditions de garantie s’annulent.
Page 46
Attention Un groupe de sécurité est obligatoire. Montez-le le plus près possible de l'appareil. Avertissement Entré la combinaison d'entrée et l'appareil, vous ne pouvez jamais monter de vanne d'arrêt ou de clapet anti-retour. Côte eau chaude 2.2.2 Voir (B) du schéma de raccordement (2.1 "Schéma de raccordement"). Note L'installation des longues conduites d'eau chaude évite les pertes énergétiques inutiles...
Remplissage é Vidange Schéma de raccordement Légende 2. groupe de sécurité (obligatoire) 3. soupape thermique (recommandée) 4. vanne d'arrêt (recommandée) 5. clapet anti-retour (obligatoire) 6. circulateur de bouclage (option) A. alimentation en eau froide B. sortie d'eau chaude C. conduit de circulation bouclage IMD-0643 R1.0 3.1 Remplissage Pour remplir l'appareil, procédez comme suit :...
Page 48
3.2 Vidange Fermez la vanne d'arrêt dans la conduite d'eau chaude. 1. Fermez le robinet d'arrivée du groupe de sécurité (2). 2. Ouvrez le robinet de vidange. 3. Purgez l'appareil (ou l'installation) pour qu'il (elle) puisse se vider complètement. Notice d’installation, Mode d’emploi, Notice d’entretien...
Effecteur l'entretien Attention L'entretien ne peut entré effectué que par un professionnel de la maintenance ou de l'entretien agréé. A chaque entretien, l'appareil doit être contrôlé côté eau et côté gaz. L'entretien doit s'effectuer dans l'ordre suivant. 1. Préparer l'entretien 2.
Page 50
Ordre du travail: 1. Faites tourner les boulons de l’ouverture de nettoyage. 2. Éliminez le couvercle et le joint. 3. Inspectez le réservoir. Éliminez la couche de calcaire accumulée et les saletés. 4. Si la couche de calcaire ne peut être éliminée manuellement, il convient de retirer le calcaire avec un détartrant.
Si, moins de trois ans après la date initiale de l'installation d'un chauffe-eau livré par A.O. Smith, après examen par et sur l'appréciation exclusive de A.O. Smith, la cuve en acier thermo vitrifié présente des fuites suite à une formation de rouille ou de corrosion du côté...
5.5 Portée de la garantie Les obligations de A.O. Smith conformes à la garantie accordée se limite à la livraison gratuite de l'entrepôt des pièces ou parties à remplacer ou de l'appareil à...
Need help?
Do you have a question about the ST Series and is the answer not in the manual?
Questions and answers