Troubleshooting Guide - EINHELL GC-SP 2275 Original Operating Instructions

Clear water pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14

11. Troubleshooting guide

Faults
The equipment
does not start
The equipment
does not pump
The equipment
does not cut out
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GC_SP_2275_SPK13.indb 18
Anl_GC_SP_2275_SPK13.indb 18
GB
Cause
- Power supply not connected
- Floating switch does trigger
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 18 -
Remedy
- Check power supply
- Raise position of fl oating switch
- Clean intake sieve with water jet
- Unkink the hose
- Place equipment correctly on shaft
bottom
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
30.01.2023 10:14:47
30.01.2023 10:14:47

Advertisement

Table of Contents
loading

This manual is also suitable for:

41.815.20

Table of Contents