Table 13-14
Information requirements for heat pump space heaters and heat pump combination heaters
Model(s):
Air-to-water heat pump:
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
For low-temperature heat pumps, parameters shall be declared for low-temperature application. Otherwise,
parameters shall be declared for medium-temperature application. Parameters shall be declared for
average climate conditions.
Item
Rated heat output(3)at Tdesignh = -10
(-11) °C
Seasonal coefficient of performance
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps:
Tj = – 15 °C (if TOL < – 20 °C)
Bivalent temperature (maximum +2°C)
Cycling interval capacity for heating
at Tj= -7°C
Degradation co-efficient
at T= -7°C
(4)
Cycling interval capacity for heating
at Tj=+2°C
Degradation coefficient
at T= +2°C
(4)
Cycling interval capacity for heating
at Tj= +7°C
Degradation coefficient
at Tj= +7°C
(4)
Cycling interval capacity for heating
at Tj=+12°C
Degradation coefficient
at Tj= +12°C
(4)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
Sound power level, indoors
Sound power level, outdoors
Contact details
(1) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to
the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the
supplementary capacity for heating sup(Tj).
(2) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Symbol Value Unit
Name and address of the manufacturer or its authorised representative.
60
MUENR-140-H12T(K)
Item
Symbol Value Unit
Seasonal space heating
energy efficiency
Active mode coef. of
performance
Net seasonal coef. of
performance
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps:
Tj = – 15 °C (if TOL < – 20 °C)
For air-to-water HP:
Operation limit temperature
(maximum-7°C)
Heating water
operating limit temperature
Cycling interval efficiency
at Tj= +7°C
Cycling interval capacity for
heating at Tj=+12°C
Cycling interval efficiency
at Tj= +7°C
Cycling interval capacity
for heating at Tj=+12°C
Supplementary heater (to be declared even if
not provided in the unit)
Rated heat output(3)
Type of energy input
Outdoor heat exchanger
For air-to-water HP: Rated
air flow rate
For water-to-water: Rated
water flow rate
For brine-to-water: Rated
brine flow rate
[yes]
[yes/no]
[yes/no]
[yes/no]
[yes/no]
[yes/no]