Symptom: You Are Feeling Too Cold (Hot) In Your Living Room; Symptom: The Water At The Tap Is Too Cold; Symptom: Heat Pump Failure; Symptom: The System Is Making Gurgling Noises After Commissioning - Daikin Altherma 3 RW Operation Manual

Table of Contents

Advertisement

8.3
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
The desired room temperature is
too low (high).
The desired room temperature
cannot be reached.
The weather-dependent curve is
set incorrectly.
8.4
Symptom: The water at the tap is
too cold
Possible cause
You ran out of domestic hot
water because of unusually high
consumption.
The desired DHW tank
temperature is too low.
8.5

Symptom: Heat pump failure

When the heat pump fails to operate, the backup heater and/or
booster heater can serve as an emergency heater. It then takes over
the heat load either automatically or by manual interaction.
▪ When Emergency is set to Automatic and a heat pump failure
occurs:
▪ For EBVH/X: The backup heater automatically takes over the
domestic hot water production and space heating.
▪ For EBBH/X: The backup heater automatically takes over the
heat load, and the booster heater in the optional tank takes over
the domestic hot water production.
EBBH/X11+16D + EBVH/X11+16S(U)18+23D
Daikin Altherma 3 R F+W
4P643605-1B – 2022.08
Corrective action
Increase (decrease) the desired
room temperature. See
"5.6.2 To
change the desired room
temperature" [ 4  12].
If the problem recurs daily, do
one of the following:
▪ Increase (decrease) the room
temperature preset value. See
the user reference guide.
▪ Adjust the room temperature
schedule. See
"5.8  Schedule
Example" [ 4  14].
screen:
Increase the desired leaving
water temperature in accordance
with the heat emitter type. See
"5.6.3 To change the desired
temperature" [ 4  12].
leaving water
Adjust the weather-dependent
curve. See
"5.9 Weather-
curve" [ 4  15].
dependent
Corrective action
If you immediately need domestic
hot water, activate the DHW tank
Powerful operation. However,
this consumes extra energy. See
"5.7.4 Using DHW powerful
operation" [ 4  13].
If the problems recurs daily, do
one of the following:
▪ Increase
the
DHW 
tank
temperature preset value. See
the user reference guide.
▪ Adjust
the
DHW 
tank
temperature
schedule.
Example:
Program
to
additionally
heat
up
the
DHW  tank to a preset value
(Eco setpoint = lower tank
temperature) during the day.
See
"5.8  Schedule screen:
Example" [ 4  14].
▪ When Emergency is set to Manual and a heat pump failure
occurs, the domestic hot water heating and space heating stops.
To manually recover it via the user interface, go to the
Malfunctioning main menu screen and confirm whether the
backup heater and/or booster heater can take over the heat load
or not.
▪ Alternatively, when Emergency is set to:
▪ auto
SH
reduced/DHW
domestic hot water is still available.
▪ auto SH reduced/DHW off, space heating is reduced and
domestic hot water is NOT available.
▪ auto
SH
normal/DHW
normally but domestic hot water is NOT available.
Similarly as in Manual mode, the unit can take the full load with
the backup heater and/or booster heater if the user activates this
via the Malfunctioning main menu screen.
When the heat pump fails,
interface.
Possible cause
Heat pump is damaged.
INFORMATION
When the backup heater or booster heater takes over the
heat load, electricity consumption will be considerably
higher.
8.6
Symptom: The system is making
gurgling noises after
commissioning
Possible cause
There is air in the system.
Incorrect hydraulic balance.
Various malfunctions.
(a)
We recommend to purge air with the air purge function of the unit
(to be performed by the installer). If you purge air from the heat
emitters or collectors, mind the following:
8 Troubleshooting
on, space heating is reduced but
off, space heating operates as
or
will appear on the user
Corrective action
See
"8.1 To display the help text
malfunction" [ 4  18].
in case of a
Corrective action
(a)
Purge air from the system.
To be performed by the installer:
1
Perform hydraulic balancing
to assure that the flow is
correctly
distributed
between the emitters.
2
If hydraulic balancing is not
sufficient, change the pump
limitation
settings
([9-0D]
and [9-0E] if applicable).
Check if
or
is displayed
on the home screen of the user
interface. See
"8.1 To display the
help text in case of a
malfunction" [ 4  18] for more
information about the
malfunction.
Operation manual
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 rfEbbx-d9wEbbh-d9wEbvx-d9w

Table of Contents