Changing Additive; Controlling Concentration - EcoloxTech E-240 System Operation Manual

Table of Contents

Advertisement

Controlling Concentration

The following settings are recommendations for reaching approximate concentrations of free available chlorine (FAC)
in solution measured in parts per million (ppm). The 3 variables below can be adjusted to change the concentration.
1.
Flow Rate (L/min) – controlled by blue valve allowing feed water to flow into system
2.
Ampere (A) - controlled by system settings
3.
Pump Speed (PS) - controlled by system settings
Using Additive Formula 1
Flow Rate 3.0 L/min
Using Additive Formula 1
Flow Rate 4.0 L/min

Changing Additive

Replenish additive tank when low. If additive runs out, the system will
stop and display Error 2.
Changing Additive Using Formula #1
Power Off system
Remove suction line and cap from additive tank
Add 2 cups of salt to additive tank
Fill remainder of additive tank with tap water
Replace cap and shake until dissolved
Replace suction line
Power On system and press "Reset" button
(Water and Food Grade Salt)
17.5 A
0 PS
85 ppm
2 PS
82 ppm
4 PS
79 ppm
6 PS
76 ppm
8 PS
73 ppm
10 PS
70 ppm
(Water and Food Grade Salt)
17.5 A
0 PS
64 ppm
2 PS
62 ppm
4 PS
60 ppm
6 PS
58 ppm
8 PS
56 ppm
10 PS
54 ppm
22.0 A
100 ppm
96 ppm
92 ppm
88 ppm
86 ppm
82 ppm
22.0 A
80 ppm
77 ppm
74 ppm
71 ppm
68 ppm
65 ppm