Controlling Concentration
The following settings are recommendations for reaching approximate concentrations of free available chlorine (FAC)
in solution measured in parts per million (ppm). The 3 variables below can be adjusted to change the concentration.
1.
Flow Rate (L/min) – controlled by blue valve allowing feed water to flow into system
2.
Ampere (A) - controlled by system settings
3.
Pump Speed (PS) - controlled by system settings
Using Additive Formula 1
Flow Rate 3.0 L/min
Using Additive Formula 1
Flow Rate 4.0 L/min
Changing Additive
Replenish additive tank when low. If additive runs out, the system will
stop and display Error 2.
Changing Additive Using Formula #1
•
Power Off system
•
Remove suction line and cap from additive tank
•
Add 2 cups of salt to additive tank
•
Fill remainder of additive tank with tap water
•
Replace cap and shake until dissolved
•
Replace suction line
•
Power On system and press "Reset" button
(Water and Food Grade Salt)
17.5 A
0 PS
85 ppm
2 PS
82 ppm
4 PS
79 ppm
6 PS
76 ppm
8 PS
73 ppm
10 PS
70 ppm
(Water and Food Grade Salt)
17.5 A
0 PS
64 ppm
2 PS
62 ppm
4 PS
60 ppm
6 PS
58 ppm
8 PS
56 ppm
10 PS
54 ppm
22.0 A
100 ppm
96 ppm
92 ppm
88 ppm
86 ppm
82 ppm
22.0 A
80 ppm
77 ppm
74 ppm
71 ppm
68 ppm
65 ppm
7