Settings & Performance
Flow Rate measured in
Liters per minute (L)
Voltage (v)
Ampere (A)
Max. ampere: 22
Min. ampere: 13
Pump Speed (PS)
Max. speed: 0
Min. speed: 19

System Alarms

Error Code
Reason
Err1
Low Flow
Err2
Low Current
Err3
High Current
Err4
Low Voltage
Err5
Fan Error
The flow rate can be controlled by tightening or loosening the inflow water valve. A
higher flow rate will decrease the concentration of free available chlorine (FAC) and a
lower flow rate will increase the concentration of FAC.
Displaying the flow rate:
1. Press and hold "Set" button for 3 seconds and release. LED display will begin to blink.
2. Press "Mode" button until liters per minute (L) setting is displayed.
The voltage is a performance measurement and is not adjustable.
Displaying the voltage:
1. Press and hold "Set" button for 3 seconds and release. LED display will begin to blink.
2. Press "Mode" button until voltage (v) setting is displayed.
The ampere is an adjustable setting. The range is from 13 to 22 ampere. Higher settings
will increase the concentration of free available chlorine (FAC).
Adjusting the ampere:
1. Press and hold "Set" button for 3 seconds and release. LED display will begin to blink.
2. Press "Mode" button until ampere (A) setting is displayed.
3. Press "Set" button to increase the ampere. Press "Reset" button to decrease the
ampere.
4. Press and hold "Mode" button for 3 seconds and release to complete.
The pump speed is an adjustable setting. The range is from 0 to 19. Lower settings will
increase the pump speed and thus increase the additive dosed into the electrolysis cell.
For most purposes, the pump speed should be kept in mid-range.
Adjusting the pump speed:
1. Press and hold "Set" button for 3 seconds and release. LED display will begin to blink.
2. Press "Mode" button until pump speed (PS) setting is displayed.
3. Press "Set" button to increase the pump speed. Press "Reset" button to decrease
the pump speed.
4. Press and hold "Mode" button for 3 seconds and release to complete.
Check the flow of the feed water into the equipment. Once corrective action has been taken
to sustain the water flow above 3 L/min, press the "Reset" button to cancel the alarm. If
unresolved, contact the service center.
Disconnect additive tank and refill with a new brine. Re-attach the tank once completely
dissolved. Press the "Reset" button to cancel the alarm. If unresolved, contact the service center.
Disconnect additive tank and refill with a new brine. Re-attach the tank once completely
dissolved. Press the "Reset" button to cancel the alarm. If unresolved, contact the service center.
The voltage is abnormally low. Please contact the service center for further assistance.
The cooling fan is not functioning. Please contact the service center for further assistance.