9.4.2.
Removal of the Master Flange
1. Unscrew the 6 screws (D).
2. Put the 2 flexes (for shutter and linear) out through each
rectangular hole, then remove the Master Flange.
9.4.3.
Removal of the 5th Lens Frame Unit
1. Confirm that the groove of Middle Frame Unit and groove
of Cam Frame are aligned. (Phase alignment)
2. Remove the 5th Lens Frame Unit by using tweezers, etc..
9.4.4.
Removal of the 1st Lens Frame Unit
1. Put the lens side up of 1st Lens Frame Unit.
(To prevent dropping of the 2nd Lens Frame Unit)
2. Rotate the 1st Lens Frame Unit clockwise fully.