  • Page 1 flow © VSD - B Inverter OPERATION AND MAINTENANCE MANUAL First Publication Date: 01/09/2020 Revision: Revision Date:...
  • Page 2: Table Of Contents

    OPERATION & MAINTENANCE CONTENTS GENERAL INFORMATION SAFETY INFORMATION SAFETY WARNINGS & PRECAUTIONS CUSTOMER / CONTRACTOR RESPONSIBILITIES Warranty Description Dimensions Technical Data Functions Protections Installation Hydraulic Connection Electrical Connection Line Connection Pump Connection Auxiliary Connector Connection Start Up Programming User Parameters Installer Parameters Alarms Troubleshooting...
  • Page 3: General Information

    General Information These instructions are to assist in the installation of the flowcon VSD - B Inverter please follow them carefully. If, having read this Operation & Maintenance Manual, there is any doubt about any aspect of the installation please don't hesitate to contact our technical team.
  • Page 4: Safety Information

    Water Solutions. This document is intended for ALL installers, operators, users and persons carrying out maintenance of this equipment and must be kept with the equipment, for the life of the equipment and made available to all persons at all times.
  • Page 5: Safety Warnings & Precautions

    Wait more than 5 minutes after turning off the power supply before performing maintenance or inspection. Hazard of electric shock. Disconnect incoming power before working on this unit. HAND-PAP WARNING! - The inverter should be protected separately against ground fault. Observe the regional regulations for electrical installation! flowcon VSD - B Inverter...
  • Page 6: Customer / Contractor Responsibilities

    exclamat CAUTION! - It is strongly recommended that all electrical equipment conforms to National Electrical Codes and local regulations. Only qualified personnel should perform installation, alignment and maintenance. The manufacturer reserves the right to alter the technical data in order to make improvements or update information. exclamat CAUTION! - Failure to observe these rules will render the guarantee invalid.
  • Page 7: Warranty

    This device complies with the directive ROHS 2002/95/EC. Description Flowcon VSD - B Inverter is an electronic control device for single phase electric pumps which enables automatic start-up and shutdown of the pump, protecting it in the event of adverse operating conditions (failure of water supply, motor overload, risk of ice).
  • Page 8: Dimensions

    In both operating modes, the device protects the pump from dry running in the absence of water on intake, by means of a combined control on flow and pressure.Operation of twin pumping units is admissible only in "P+P" mode. Dimensions Technical Data Mains power: single phase 115-230Vac ±10% - 50/60Hz...
  • Page 9: Functions

    Configurable relay output • Removable electrical terminals to facilitate wiring. • Alarm log Protections • Dry Running • Motor current control protection • Overpressure cut-out • Anti-freeze protection • Prevention of mechanical pump part seizure flowcon VSD - B Inverter...
  • Page 10: Installation Hydraulic Connection

    Installation Hydraulic Connection Flowcon VSD - B Inverter Inverter must be installed on the pump delivery in a horizontal or vertical position, in observance of the flow direction indicated by the arrow on the cover. The water on the pump outlet passes through the device for subsequent distribution to the various utilities.
  • Page 11 Connect the intake lines of the pumps to a common manifold and install one inverter on the delivery line of each electric pump. The device outlet couplings must be connected to a single delivery manifold, which must be connected to the expansion vessel. flowcon VSD - B Inverter...
  • Page 12: Electrical Connection

    Electrical Connection Insert the electric wires in the cable clamps, observing the correct order of assembly for all components Tighten down the threaded nuts to avoid traction and rotation of the cables from the exterior. The central cable clamps for the auxiliary contact is blank; if you wish to insert a wire for remote control (or electric float), pierce the plastic nut by means of a screwdriver after removing the nut from the unit.
  • Page 13: Line Connection

    The type of electric cable must correspond to the conditions of use (use in domestic rooms, dry or wet, for installation indoors or outdoors). Pump Connection Flowcon VSD - B Inverter can be installed on single phase pumps with 230Vac power supply, already fitted with capacitor. Therefore at the time of electrical connections, ensure that...
  • Page 14: Auxiliary Connector Connection

    Auxiliary Connector Connection The Flowcon VSD - B Inverter is equipped with a connector to make auxiliary contacts available for additional functions, interfacing the device with other external equipment. The functions of each terminal depend on the settings of the parameter “Aux. Con.” According to the diagram below.
  • Page 15 5 and 6 provide a relay output that is activated in the event of an alarm. The parameter "Aux. Con.” can only be set to “4” if the current operating mode is “P+P” (pressure+pressure). flowcon VSD - B Inverter...
  • Page 16: Start Up

    After making all the electrical connections and ensuring the correct condition of all components, close the unit cover and power up the system. The Flowcon VSD - B Inverter Inverter starts up the pump automatically to enable circuit filling. If the pump does not start, or anomalous vibrations are detected, ensure correct connection of the pump and relative capacitor.
  • Page 17: User Parameters

    "master" or "slave" status by means of the letter "m" or "s". Language: the language of the menus and alarm messages can be personalised as required. Use keys + and – to modify the parameter value. flowcon VSD - B Inverter...
  • Page 18: Installer Parameters

    Installer Parameters These parameters are located in concealed screens and are normally only modified during the installation phase. To access these pages, press and hold “+” and “-“simultaneously for 5 seconds. After accessing the concealed menu, use the arrow key “>>” to scroll through the screens and keys “+”...
  • Page 19 “OFF” appears on display. CAUTION: the factory setting is OFF and therefore a maximum current value must be set to activate the protection. Auxiliary Contact: this parameter enables the user to assign a specific function to the auxiliary contacts available on the Flowcon VSD - B Inverter Inverter flowcon VSD - B Inverter...
  • Page 20 (mode set to P+P and Aux. Con. set to “4”), this parameter can be set to define the secondary pump deactivation threshold. The secondary pump where the Flowcon VSD - B Inverter is installed, is started up, on request of the inverter controlling the primary pump, when the pressure falls below Pmin.
  • Page 21: Alarms

    If the error occurs frequently, try to increase the parameter Plimit or contact the installer for assistance. To remove the error message from the display immediately, simply press the central key “reset”. flowcon VSD - B Inverter...
  • Page 22: Troubleshooting

    Troubleshooting When one of the system valves is opened the pump does not start or starts only after a few seconds. The set Pmin value is too low, or a check valve has been fitted downline of the device. Check the setting of the parameter Pmin.
  • Page 23: Maintenance

    Maintenance The Flowcon VSD - B Inverter Inverter has been designed to reduce maintenance requirements to a minimum. Always observe the following instructions to ensure prolonged efficiency of the device: - Never allow the device to reach temperatures below 4° C; if this is not possible, ensure that all the water in the circuit is drained to prevent damage to the plastic housing of the device if ice forms;...
  • Page 24 Unit 1 Lock Flight Buildings, Wheatlea Industrial Estate, Wigan, Greater Manchester WN3 6XP United Kingdom 9001 : 2015 REGISTERED Membership No. 700106 Certificate No. 185352020 Copyright © 2020 • All Rights Reserved • Flowtech Water Solutions Limited • Company Number: 05125479 • VAT Number: 836 8024 19...