3.11.3 Waveform storage: regardless of downloaded from PC using software or edited using
the keyboard, the user-defined waveforms data are stored in volatile memory, they will vanish
on turning off the generator. If you want to preserve the waveform for a long time, please
store the data.
Press 【 Menu 】 key, select "Store" option and input with the keyboard one waveform
sequence number from 11# ~ 15#, press 【 # 】 key, then the current waveform will be
persevered in specified non-volatile memory and will not vanish even turning off the generator.
Of course when you store a new waveform, the selected memory will be overwritten by the
new data, in order to prevent that several waveform sequence No. are continuously stored by
carelessly rotating the knob, the knob is locked under "Store" option and the users could only
use keyboard to store data.
3.11.4 Waveform recall: after the user-defined waveform is stored, press 【 Shift 】
【 Waveform 】 key to set waveform sequence number, to recall user-defined
waveform of this sequence number.

3.12 Setting parameter storage

A lot kinds of working parameters of the generator could be set during operation,
such as waveform, frequency, amplitude and so on, total more than 40 kinds, which
are totally called as the setting parameter of the generator.
3.12.1 Setting parameter storage: the generator has 6 non-volatile memories, to store 6
groups of setting parameters respectively, which will not lose even if cutting off the power.
The generator uses location 0# to hold the default settings, to prevent the default
setting parameter from being changed, the 0# memory area is designed to not allow
storage operation. Use 1# ~ 5# memory area to store user-defined setting parameter.
The 1# memory area stores the power-on setting parameters, the users may store
setting parameters usually used to the 1# memory area, which will be automatically
recalled when generator power on or system reset.
Under CHA tone function, press 【 Menu 】 key and select "Store" option, then input
memory area within 1# ~ 5# with the keyboard and press 【 # 】 key, the current setting
parameters of the generator will be stored to the non-volatile memory with this specified
memory area number, these setting parameters will not lose even if power off the generator. A
new group of setting parameter stored will cover the former data in this memory area, to
prevent storing data to more than one memory area continuously by rotating the knob
carelessly, and under "Store" option, the knob function is locked and the users could