Riello RS 68/EV BLU Installation, Use And Maintenance Instructions page 52

Forced draught gas burners progressive two-stage or modulating operation
Table of Contents

Advertisement

Parameter
No.
Description
403
VSD control curve ratio (only curve setting)
500
POSITIONING OF SERVOMOTORS
Position of the fuel servomotor in absence
of flame
501
Index 0 = standby position
Index 1 = pre-purging position
Index 2 = post-purging position
Position of the air servomotor in absence of flame
Index 0 = standby position
502
Index 1 = pre-purging position
Index 2 = post-purging position
VSD speed without flame
Index 0 = standby speed
503
Index 1 = pre-purging speed
Index 2 = post-purging speed
522
Acceleration
523
Deceleration
VSD/PWM activation
542
0 = Deactivated
1 = Activated
Minimum modulation limit
545
Not defined = 20%
Maximum modulation limit
546
Not defined = 100%
600
SERVOMOTORS
Tolerance limit for position check (0.1°)
Index 0 = fuel
Index 1 = air
606
More serious position error, where a defect has cer-
tainly been detected
- > Stop range: (P 606 - 0.6°) a P606
VSD speed standardisation control
Negative value error diagnostics (see error code 82)
641
0 = standardisation deactivated
1 = Standardisation active
Standardised speed
642
Index 0 = speed 1
Index 1 = speed 2
Analogue exit configuration
0 = DC 0...10 V
645
1 = DC 2...10 V
2 = DC 0 / 2...10 V
700
LOG OF THE ERRORS
701
Error chronology: 701-725.01.Code
Error chronology: 701-725.02.Diagnostic code
Error chronology: 701-725.03.Error class
Error chronology: 701-725.04.Phase
Error chronology: 701-725.05.Start-up meter
725
Error chronology: 701-725.06.Load
900
PROCESS INFORMATION
Actual output
903
Index 0 = fuel
Index 1 = air
Position of the servomotors
922
Index 0 = fuel
Index 1 = air
935
Absolute speed
936
Standardised speed
Heat source active
1 = output during the definition of the curves
2 = manual output
942
3 = BACS output
4 = analogue input output
5 = output of the external load regulator contacts
20068463
Start-up, calibration and operation of the burner
No. ele-
ments
13
3
3
3
1
1
1
1
1
2
1
2
1
25
25
25
25
25
25
2
2
1
1
1
Value range
Unit of
Modifica-
measure
tion
Min.
(°)
Modification
20°
(°)
Modification
(°)
Modification
(°)
Modification
s
Modification
5 s
s
Modification
5 s
-
Modification
0
Modification /
%
20%
zero setting
Modification /
%
20%
zero setting
(°)
Modification
0.5°
-
Modification
-25
-
Reading only
650
-
Modification
0
-
Reading only
0
-
Reading only
0
-
Reading only
0
-
Reading only
0
-
Reading only
0
%
Reading only
0%
%
Reading only
0%
(°)
Reading only
-50°
-
Reading only
0
%
Reading only
-200%
-
Reading only
0
50
GB
Degree of
Default
accuracy
setting
Max.
0°; 100°;
100°
0.1°
50°; Not
defined
90°
0.1°
0°; 0°; 15°
90°
0.1°
0°; 90°; 45°
100°
0.1°
0°; 100°; 50°
20s
1s
10s
20s
1s
10s
1
1
0
100%
0.1%
Not defined
100%
0.1%
Not defined
0.1°
1.7°; 1.7°
1
1
0
6500
0.1
Not defined
2
1
2
255
1
0
255
1
0
6
1
0
255
1
0
99999999
1
0
100%
0.1%
0%
100%
0.1%
0%
150°
0.01°
6553,5
0.1
0
200%
0.1%
0%
255
1
0
Acces mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Service Mode
Info mode
Info mode
Info mode
Info mode
Info mode
Info mode
Info mode
Info mode
Service mode
Info mode
Service mode