VK / TR SERIES GAS FRYERS
FILTERING PROCEDURE – KleenScreen PLUS® Models ONLY
Filter shortening at least once a day.
1.
2. Vulcan recommends adding an oil treatment media to the oil prior to filtering.
3. Make sure that the filter drawer is closed completely and that the suction tube and
receptacle block are in the correct position. Fig. 5
4. A cold fryer will not drain easily. Always filter shortening between 250°F
and 350°F. The shortening in the cold zone area will remain hard if the heat is only on for
a few minutes. If necessary, use the clean-out rod to carefully move the hard shortening
to an area above the cold zone where it will melt.
5. Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan. Then open
the drain valve all the way. Please note the gas power burner will automatically turn off at
this point. DRAINING will appear on the digital display for solid state digital (D) and
DRAINING OIL will display on computer models (C).
VULCAN-HART
Hot oil and parts can cause burns. Use care when operating,
cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move
fryer without draining all frying compound from the tank.
Never run water or boil out solution through filter and motor / pump. Doing so
will void your fryer warranty.
Filter ONLY one fry tank at a time
Do NOT turn off the power to the fryer. Leave power on.