Polarising Plate (not supplied)
The purpose of the polarising plate is to ensure that the sensor does
not rotate from the correct position, i.e. pointing vertically
downwards, during transport or installation.
The two overall dimensions marked 'SEE TEXT' need to be made
such that when the plate is positioned against the inner face of the
luminaire end cap, it cannot rotate.
The 3.5mm 'tab' should be located closest to the ceiling (away from
the lamp). The 6.0mm slot is optional and is to allow the wires to
pass through for ease of assembly.
Material can be plastic sheet, minimum thicknesss 1.0mm,
recommended thickness 1.5-2.0mm, or mild/stainless steel sheet,
minimum thickness 0.6mm, recommended thickness 1.0-1.6mm.

Electrical Connections

Fig. 6
Blue
Brown
Black
Fig. 7
Brown - Live
Blue
- Neutral
Black
- Switched live
SUPPLY
L N E
L N E
L N E
LOAD
LOAD
Maximum Total Load not to exceed
that specified for a Single Detector
Always check product label before connecting.
L N E
LOAD
- 3 -
SEE TEXT
3.5
20
6.0
Fig. 5
Blue
Brown
Black
Multiple Detectors
may be connected
in parallel, as is
shown above, to
control the same
Maximum Load