2.7 Condensate drain connection

IMPORTANT
The boiler has an internal trap for draining condensate. Install the push on hose "B" & sediment bowl before commis-
sioning, the boiler fill the trap with approx. 0.5 L of water and connect the hose to a solvent welded waste system. For
safety reasons the hose must form a tight seal into the waste system.
B
ATTENTION: THE UNIT MUST NEVER BE OPERATED WITH THE TRAP EMPTY!
OTHERWISE THERE IS A DANGER THAT PRODUCTS OF COMBUSTION COULD ENTER THE ROOM.
18
BLUEHELIX TECH RRT
fig. 25- Condensate drain connection
cod. 3541P151 - Rev. 00 - 11/2018
18S / 24S / 30S