Features
Handles Liquids and solid waste
materials up to 2" diameter
Cast iron pump housing with protective
epoxy coating for corrosion resistance
Oil-filled motor housing for lifetime
lubrication and rapid heat dissipation
Stainless steel screws, bolts, handle
and switch guard
Mechanical seals (stainless steel spring,
nitrile parts, carbon and ceramic faces)
Thermal overload protection
Integral snap-action float switch —
Automatic operation has 11" to 14"
"On" level range and 5" to 8"
"Off" level range
Piggyback mechanical float switch —
Automatic operation has 15" to 17"
"On" level range and 8" to 10"
"Off" level range
PSC type motor with upper and lower
ball bearings on 10S-CIA-SFS
Split-phase type motor on 10S-CIA-RFS

Advertisement

loading

Summary of Contents for Little Giant 10S-CIA Series

  • Page 1 Wastewater 10S-CIA Series Features Handles Liquids and solid waste • materials up to 2" diameter Cast iron pump housing with protective • epoxy coating for corrosion resistance Oil-filled motor housing for lifetime • lubrication and rapid heat dissipation Stainless steel screws, bolts, handle •...
  • Page 2: Dimensional Outline

    Steel Bearings Upper & lower ball bearings P.O. Box 12010 Oklahoma City, OK 73157-2010 Phone: 1.800.701.7894 ©2008 Franklin Electric Co., Inc. Fax: 1.800.678.7867 Little Giant ® is a registered trademark of Franklin Electric Co., Inc. www.LittleGiantPump.com Form 995204 — 04/08...
  • Page 3: Safety Guidelines

    removed from the surface quickly by placing newspapers on the 10E-CIA-SFS water surface to soak up the oil. 10S-CIA-SFS Franklin Electric Co., Inc. The pump motor is equipped with an automatic resetting thermal P. O. Box 12010 protector and may restart unexpectedly. Protector tripping is an Oklahoma City, OK 73157-2010 Submersible 405.947.2511 •...
  • Page 4: Maintenance

    Removal of these screws 2. Place the pump on a hard, level surface. Never place the pump by anyone other than an authorized Little Giant service center will directly on clay, earth, or gravel surfaces.
  • Page 5: Replacement Parts

    REPLACEMENT PARTS MODEL/CATALOG NO. ITEM PART DESCRIPTION 110352 Cover assembly, 10ft, (115v) 110353 Cover assembly, 25ft, (115v) 110354 Cover assembly, 25ft, (230v) 909022 Screw/washer, 10-24 x 5/8 928002 Seal ring, nitrile 950250 Switch 902431 Screw, 8-18 x 1/2 950507 Capacitor assembly, 10-SFS 110101 Bracket, capacitor 106362 Float 902516 Screw, tapping, 10-24 x 1/2...
  • Page 6: Limited Warranty

    PUMPS: 24 months from date of purchase or 30 months from date of manufacture, whichever occurs first. LABOR, ETC. COSTS: Little Giant shall in no event be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or affixing any Little Giant product, part or component thereof.

This manual is also suitable for:

10s-cia-sfs10s-cia-rfs511550511555511565511500