A-7
POWER SOURCE TO RED-D-ARC LN25™ PRO
EXTREME CABLE CONNECTION DIAGRAMS
ACROSS THE ARC SET-UPS
CV
Power Sources with Stud Connectors and
Remote/Local Switch (See Figure A.6)
CV-400
CV-655
DC-400
DC-600
DC-655
V450-Pro
SAE 400 with CV adapter
Engine Driven welder with
Wire Feed Module
Ranger 250 GXT
Place the power source Remote/Local switch in the
Local position.
Place CV/CC switch in the feeder in the "CV" position.
CV Power Sources with Stud Connectors and no
Remote/Local Switch. (See Figure A.7)
Ranger 250, 250 LPG
Ranger 305G, 305D
Ranger 10,000
Ranger 3 Phase
Ranger 225, 225GXT
Commander 300
Vantage 300, 400, 500
Air Vantage 500
Place CV/CC switch in the feeder in the "CV" position.
INSTALLATION
FIGURE A.6
Jumper
Electrode
Work
See Magnum Pro Literature
FIGURE A.7
Electrode
Work
See Magnum Pro Literature
RED-D-ARC LN25™ PRO EXTREME
(Red-D-Arc LN25™
PRO Extreme)
K#
K2613-6
KP1695-XX
KP1696-XX
KP1697-XX
K1803-XX
K484
(Red-D-Arc LN25™
PRO Extreme)
K#
K2613-6
KP1695-XX
KP1696-XX
KP1697-XX
K1803-XX
A-7
Work clip
Description
(Red-D-Arc LN25™
PRO Extreme)
Drive Roll Kit
Welding Gun
CV power Source
Welding Cables
Jumper Plug Kit
Work clip
Description
(Red-D-Arc LN25™
PRO Extreme)
Drive Roll Kit
Welding Gun
CC power Source
Welding Cables

Advertisement