Red-D-Arc LN25 PRO EXTREME Operator's Manual page 22

Hide thumbs Also See for LN25 PRO EXTREME:
Table of Contents

Advertisement

B-5
5. SET-UP MENU
Preparation for WFS Calibration:
• Place the CV/CC switch in CV.
• Set the display to the desired wire feed speed
(example: 400 inches per minute)
• Measure the actual wire feed speed (example: 405
inches per minute)
• Place the WFS knob in the 12 oʼclock position.
To enter the set-up menu, use paper clip to press the
small button located on the case front.
WIRE FEED SPEED UNITS
To change the wire feed speed units:
Rotate the WFS knob to the left to use "inches/minute"
for the wire feed speed units.
Rotate the WFS knob to the right to use
"meters/minute" for the wire feed speed units.
US
Then rotate the WFS knob to the 12 oʼclock position.
OPERATION
PUSHBUTTON
EUro
RED-D-ARC LN25™ PRO EXTREME
WFS CALIBRATION
Measurements for adjusting the WFS calibration must
be made before entering the set-up menu. When first
entering WFS Calibration, the calibration factor dis-
played is based upon the position of the knob and
does not reflect the actual calibration factor stored in
memory.
If no changes are being made to the calibration, then
press the set-up button to enter WFS Knob Range.
While in the set-up menu, adjust the calibration factor in
the following example:
Actual WFS
= Caibration Factor
Set WFS
Press the set-up button when calibration factor is set.
B-5
405
Example:
= 1.01
400

Advertisement

Table of Contents
loading

Table of Contents