Payne PG95 Installation, Start-Up, Operating And Service And Maintenance Instructions page 67

Single-stage 4-way multipoise condensing gas furnace
Table of Contents

Advertisement

SINGLE-STAGE
ON/OFF Switch
1/2" NPT Inlet
1/8" NPT Inlet
Pressure Tap
Representative drawing only, some models may vary in appearance.
Standard Capacity Gas Valve without Tower Pressure Ports
White Rodgers
MODEL 36J60(515
24V 50/60HZ .280 AMPS
MAX. PRESS ½ PSI
REG, 1.5" W.C.
½" NPT Inlet
⅛" NPT Inlet
Pressure Tap
Representative drawing only, some models may vary in appearance.
26,000 BTUH Low Capacity Gas Valve without Tower
Pressure Ports
MANIFOLD PRESSURE TAP
SET SCREW: 3/32" HEX HEAD
ACCEPTS 5/16" HOSE CONNECTION
1/2" NPT
INLET
INP
INLET PRESSURE
TAP SET SCREW:
3/32" HEX HEAD
ACCEPTS 5/16"
HOSE CONNECTION
1/8" NPT INLET
PRESSURE TAP
Representative drawing only, some models may vary in appearance.
Standard Capacity Gas Valve with Tower Pressure Ports
Regulator Seal Cap
Regulator Adjustment
Regulator Seal Cap under Cap
1/2" NPT Outlet
1/8" NPT Manifold
Pressure Tap
A11153
1.5" W.C.
½" NPT Outlet
Regulator Seal Cap
Regulator Adjustment
Regulator Seal Cap
ON/OFF Switch
Under Cap
A170147
1/2" NPT
OUTLET
OUTP
REGULATOR SEAL CAP
ON/OFF SWITCH
(REGULATOR ADJ.
UNDER CAP)
A170118
MANIFOLD PRESSURE TAP
SET SCREW: 3/32" HEX HEAD
ACCEPTS 5/16" HOSE CONNECTION
1/2" NPT
INLET
INP
INLET PRESSURE
TAP SET SCREW:
3/32" HEX HEAD
ACCEPTS 5/16"
HOSE CONNECTION
1/8" NPT INLET
PRESSURE TAP
Representative drawing only, some models may vary in appearance.
26,000 BTUH Low Capacity Gas Valve with Tower Pressure
Fig. 59 − Gas Valves with Tower Pressure Ports
Fig. 60 − Orifice Hole
THERMOSTAT SUBBASE
TERMINALS WITH
THERMOSTAT REMOVED
(ANITICIPATOR, CLOCK, ETC.,
MUST BE OUT OF CIRCUIT.)
R Y W G
10 TURNS
FROM UNIT 24-V
CONTROL TERMINALS
5.0 AMPS ON AMMETER
EXAMPLE:
10 TURNS AROUND JAWS
Fig. 61 − Amp. Draw Check with Ammeter
67
1/2" NPT
OUTLET
OUTP
REGULATOR SEAL CAP
1.5"
ON/OFF
(REGULATOR ADJ.
W.C
SWITCH
UNDER CAP)
.
A170140
Ports
BURNER
ORIFICE
A93059
HOOK-AROUND
AMMETER
0.5 AMPS FOR THERMOSTAT
=
ANTICIPATOR SETTING
A96316

Advertisement

Table of Contents
loading