AT+CNBTRIALS=1,2
OK
Need to set before sending data
command format
AT+CRM=?
AT+CRM?
AT+CTXP=<reportMode>,[re
portInterval]
<reportMode>:
0- non-periodic reporting data;
1-periodic reporting data;
<reportInterval>: This parameter is only available when reporting data periodically.
Time interval for periodic reporting of data, unit: s.
For different DRs, the allowable minimum cycle is different, which is defined by cycle
level, as shown in the following table.
Rate\Period(s)\Level LV1 LV2
DR0 150 300
DR1 75 150
DR2 35 70
DR3 15 30
DR4 10 20
DR5 5 10
AT+CRM=1,10
OK
Need to set before sending data
command format
AT+CTXP=?
AT+CTXP?
AT+CTXP=<value>
<value>: is the transmission power, the factory value is 0
0 - 17dBm
E78-915LN22S(6601) User Manual
response
+CRM: " reportMode " , " reportInterval "
OK
+CTXP:<reportMode>,[reportInterval]
OK
OK
response
+CTXP: " value "
OK
+CTXP:<value>
OK
OK