  • Page 1 G R O U P, I N C. Operator’s Manual ACF-10 Series Acoustical Flow Sensor for Solids Rev. 1a, 2/03 Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • E-mail: sales@apgsensors.com...
  • Page 2: Table Of Contents

    Installation ..................6 Wiring ..................... 7 Adjustment ..................8 Cautions on Handling ..............11 Check Up ..................12 Dimensions ................... 13 Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 3: Warranty

    No representation or warranty, express or implied, made by any sales representative, distributor, or other agent or representative of APG which is not specifically set forth herein shall be binding upon APG. APG shall not be liable for any incidental or consequential damages, losses or expenses directly or indirectly arising from the sale, handling, improper application or use of the goods or from any other cause relating thereto and APG’s liability hereunder,...
  • Page 4: Introduction

    The ACF-10 can be easily attached to existing pipes with straps. The ACF-10 is easily adjusted with the use of four LED. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 5: Specifications

    Construction ..... Drip-proof (IP54) Installation ....... Attaching band or metal fixtures (option) Wire Inlet ......PF1/2 (cable gland method, gasket I.D. ø10 and ø8) Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 6: Principle Of Operation

    When the grains flows, by adjusting to amplify only the component of signals, the signals can be increased to a desired voltage. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 7: Installation

    Unless the receiving part is in contact firmly with the wall, the sensor will be insensitive. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 8: Wiring

    Rev. 1a, 2/03 ACF-10 Series • Wiring Line Supply Voltage: 24-264V AC/DC Relay Contact Output: 240V 2A AC (resistive load) Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 9: Adjustment

    The red LED (4 pieces) indicate the intensity of input signals. When the LED illuminate, the relay will be switched on. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 10 ❍ just to illuminate RY ON LED ★ Stop the flow of grains. ZERO RY ON ❊ ❍ ❍ ❍ ❍ Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 11 ON DELAY: Delay in output for change from non-detection to detection. OFF DELAY: Delay in output for change from detection to non-detection. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 12: Cautions On Handling

    Use the solderless terminal with the size as shown in the figure below. Recommended press-fit terminal: nominal 1.25-3.5 Use the terminal with insulating tube. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 13: Check Up

    OFFSET trimmer in the center to tap lightly the receiving part by a finger nail. When the illumination of the LED moves rightward from the zero point, the operations are regarded as normal. Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 14: Dimensions

    Rev. 1a, 2/03 ACF-10 Series • Dimensions — in./mm 1.97 0.02 1.65 4.21 3.15 Automation Products Group, Inc. APG...Providing tailored solutions for measurement applications Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 15 AUTOMATION P R O D U C T S G R O U P, I N C. APG...Providing tailored solutions for measurement applications Automation Products Group, Inc. Tel: 1/888/525-7300 1/435/753-7300 Fax: 1/435/753-7490 e-mail: sales@apgsensors.com www.apgsensors.com Automation Products Group, Inc. 1025 W. 1700 N.