Operator's Manual
PG10
Full Access
DOC. 9003470
Rev B2 8/16
Automation Products Group, Inc.
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • E-mail: sales@apgsensors.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for APG PG10

  • Page 1 AUTOMATION P R O D U C T S GROUP, INC. Operator’s Manual PG10 Full Access DOC. 9003470 Rev B2 8/16 Automation Products Group, Inc. Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • E-mail: sales@apgsensors.com...
  • Page 2: Table Of Contents

    PG10 Rev. B2, 8/16 Table of Contents Warranty ....................3 Programming the PG10 ............... 4-36 Menu Flow Chart ................... 5 Mode Setting ..................6 Accessing/Exiting the Setup Menu ............7 Maximum/Minimum Function ..............8 Units of Measure ................9-10 Using Custom Units ..............10 Peak-Hold Feature ................
  • Page 3: Warranty

    Rev. B2, 8/16 • Warranty and Warranty Restrictions This product is covered by APG’s waranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit https://www.apgsensors.com/about-us/terms-conditions.
  • Page 4: Programming The

    PG10 Rev. B2, 8/16 Programming the PG10 Each of the 4 buttons on the PG10 performs dual functions; one within the setup menu system, and another when in standard operating mode. Mode Button MODE Primary Function: Used to access the main setup menu or to return to the main setup menu from any of the submenus.
  • Page 5: Menu Flow Chart

    PG10 Rev. B2, 8/16 CUSTOM ONLY < 120 PSI CUSTOM MAXMIN MBAR INHG MMHG UNITS SET MULTIPLIER VALUE NEWTON TONNES P HOLD CUSTOM CUSTOM ONLY > 120 PSI KGCM ADVSET CMHG AUTO OFF, 2MIN, 4MIN, 8MIN, 16MIN, 32MIN, LIGHT TARE...
  • Page 6: Mode Setting

    PG10 Rev. B2, 8/16 • Operating Modes: The PG10 has 4 standard operating modes to choose from: Mode 000: Full Access - Provides access to all menu settings. If no buttons are pushed for 1 minute, the gauge will revert back to Mode 003 (factory default).
  • Page 7: Accessing/Exiting The Setup Menu

    PG10 Rev. B2, 8/16 Accessing the Setup Menu: Step 1: Simultaneously press and hold for approximately 3 ENTR MODE seconds. This will bring up the 3 digit mode number. Step 2: Using to change the value of the flashing digit, and ENTR to advance to the next digit, change the mode number to 000.
  • Page 8: Maximum/Minimum Function

    PG10 Rev. B2, 8/16 • Maximum/Minimum Reset (MAXMIN): Pressing the button while in operating mode will cycle between displaying the present pressure reading, the maximum pressure reading and the minimum pressure reading. The maximum and minimum readings will be stored until the gauge is powered down or the max/min readings are reset.
  • Page 9: Units Of Measure

    PG10 Rev. B2, 8/16 • Units of Measure (UNITS): Allows the user to select the unit of measure to be displayed as the pressure reading. Options: For gauges over 120 psi: (pounds per square inch) (bar) (kilopascals) *CUSTOM (see “Using Custom Units” on next page)
  • Page 10: Using Custom Units

    PG10 Rev. B2, 8/16 Using Custom Units (CUSTOM): The Custom Units setting allows the user to display a volumetric weight by applying a conversion factor to the pressure reading. NOTE: The conversion factor must be calculated using PSI as the base unit of measure.
  • Page 11: Peak-Hold Feature

    PG10 Rev. B2, 8/16 • Peak-Hold (P HOLd): When the Peak-Hold is enabled, the gauge will display the “peak” or maximum pressure reading since the gauge was powered on or the Max/Min value was reset. NOTE 1: When the Peak-Hold feature is enabled, the...
  • Page 12: Advanced Settings

    (>1.8V). NOTE 2: Selecting LIGHT will keep the gauge continuously powered as long as the light sensor in the PG10 detects adequate light levels. When the environment is sufficiently dark, the PG10 will automatically shut down until the lighting once again reaches the threshold of the light sensor.
  • Page 13: Decimal Place

    PG10 Rev. B2, 8/16 Decimal Place (dEC PL): The reading can be set to display in High Resolution (HI RES), Medium Resolution (MEdRES) or Low Resolution (LO RES) mode. Switching between resolutions will shift the displayed reading by one decimal place position.
  • Page 14: Sample Rate

    PG10 Rev. B2, 8/16 Sample Rate (SAMPLE): Adjusts the rate at which the gauge takes sample readings. NOTE: Setting the Sample Rate to “SLOW” will help preserve battery life (when applicable) and will also help to smooth rapidly fluctuating readings.
  • Page 15: Bar Graph

    PG10 Rev. B2, 8/16 Bar Graph 0% (bAR 0) & Bar Graph 100% (bAR100) Settings: Allows the user to define the reading values associated with 0% and 100% on display bar graph. Bars will appear/disappear in 10% increments of the the 270 total span between the two values.
  • Page 16: Range Adjustment

    PG10 Rev. B2, 8/16 Full-Scale Range Adjust (RANGE): Allows the user to adjust the reading at full-scale pressure. The reading can be adjusted by +/-10% full-scale. NOTE: The pressure reading must be within 5% of the full-scale value in order to make Range adjustments.
  • Page 17: Fast Calibration

    PG10 Rev. B2, 8/16 Fast Calibration (CALIBR): Allows the user to perform a fast calibration of the zero and span. NOTE: Both zero pressure and full-scale pressure must be applied to the gauge in order to complete the quick calibration process.
  • Page 18: Datalogging

    Logging Sample Rate setting (see page 20). The PG10 can be configured to log continuously, based solely on the Logging Sample Rate setting, or to log only when user defined pressure conditions exist (event logging).
  • Page 19: Date & Time

    PG10 Rev. B2, 8/16 Date (DATE) and Time (TIME): Used to set the date and time, which will be used as the reference for the time stamp of the logged readings. NOTE: Hours are set using the 24 hour system (e.g. 1:00 p.m. is 13:00).
  • Page 20: Logging Sample Rate

    PG10 Rev. B2, 8/16 Logging Sample Rate (SAMPLE): Determine the interval between logged readings whenever logging is activated. Options: 1 second (1s), 30 seconds (30s), 1 minute (1m), 30 minutes (30m), 1 hour (1h), and 1 day (1day). Setting the Logging Sample Rate:...
  • Page 21 Used to enable/disable datalogging, and to clear all logged records. Setting the Logging Type (continuous or event): The PG10 can be set to continuously log readings or to only log readings based on the Trip Relay status. NOTE 1: Gauges not equipped with relay outputs will still use the Trip Relay settings to define the pressure range(s) for the event logging (see pages 30-32 programming details).
  • Page 22: Event Logging

    PG10 Rev. B2, 8/16 Setting Event Logging: When Event Logging is enabled, the gauge will log readings based on the status of one or both of the Trip Relays (see Trip Relay programming on pages 30-32). NOTE: Gauges not equipped with relay outputs will still use the Trip Relay settings for event logging.
  • Page 23: Disable/Clear Logging

    PG10 Rev. B2, 8/16 Disabling Logging (STOP) and Clearing Logged (CLEAR) Readings: Step 1: Press to enter the main setup menu. MODE Step 2: Press to cycle through the options until dATLOG is displayed. Step 3: Press ENTR to enter the Datalogging menu.
  • Page 24: Viewing Logged Readings

    PG10 Rev. B2, 8/16 Viewing Logged Readings (VIEW): The latest reading will be the first record displayed when viewing the logged readings. MODE Step 1: Press to enter the main setup menu. Step 2: Press to cycle through the options until dATLOG is displayed.
  • Page 25: Enabling/Disabling The Clock

    PG10 Rev. B2, 8/16 Enabling and Disabling the Clock on the main display (CLOCK): When enabled, the time will be displayed on the lower line (menu line) of the main display, alternating every two seconds with the unit of measure.
  • Page 26: Tare Feature

    NOTE 2: If the maximum gross full-scale pressure value is reached while the Tare feature is enabled, the PG10 will automatically disable the Tare feature and return to reading the gross pressure in order to help prevent the user from accidently overpressuring the gauge.
  • Page 27: Default

    PG10 Rev. B2, 8/16 • Default (dEFAUL): Used to reset the gauge to the factory default settings. Resetting the gauge to factory default settings: MODE Step 1: Press to enter the main setup menu. Step 2: Press to cycle through the options until dEFAUL is displayed.
  • Page 28: Outputs

    PG10 Rev. B2, 8/16 • OUTPUT: Used to configure any optional gauges outputs, such as an analog signal or trip point relays. Analog Low (AL SET) & Analog High (AH SET) Setpoints: Allows the user to define the reading values associated with the Low Analog signal (i.e.
  • Page 29 PG10 Rev. B2, 8/16 Analog Low (AL CAL) & Analog High (AH CAL) Calibration: Allows the user to calibrate or “trim” the endpoints of the analog signal output (i.e. 4mA & 20mA or 0V & 2V/5V) Calibrating the Analog Signal End-Points: Step 1: Use a calibrated meter to monitor the analog output signal.
  • Page 30 PG10 Rev. B2, 8/16 Trip Points: The PG10 can be configured with dual relay trip-point outputs. The relays are SPDT mechanical in form. Each trip point (T1 and T2) can be configured to perform one of six different logic functions as described below and on the chart on the next page.
  • Page 31 PG10 Rev. B2, 8/16 Trip Pressure: determines the lower pressure point for the trip output function. Trip Window: determines the pressure range between the lower and upper trip pressures. Used for Types 1, 2, 4, 5 (see chart below). Automation Products Group, Inc.
  • Page 32: Trip Point Outputs

    PG10 Rev. B2, 8/16 Setting the Trip Point Outputs: MODE Step 1: Press once to enter the main setup menu. Step 2: Press to cycle through the options until OUTPUT is displayed. ENTR Step 3: Press to access the Output Settings menu.
  • Page 33: Communications

    • Communications (COMM): Used to configure RS-485 Modbus communications settings (on models equipped). NOTE: The PG10 can function only as a slave device. Baud Rate (bAUd R): Sets the baud rate for the RS-485 communications. Options are 2400, 9600, 19200, 33400...
  • Page 34 PG10 Rev. B2, 8/16 Parity (PARITY): Sets the parity for the RS-485 communications. Options: None, Even, Odd Setting the Communications Parity: MODE Step 1: Press to enter the main setup menu. Step 2: Press to cycle through the options until COMM is displayed.
  • Page 35 PG10 Rev. B2, 8/16 Stop Bits (STOPbT): Sets the number of stop bits for the RS-485 communications. Options: 1 Stop bit, 2 Stop bits Setting the number of Stop Bits: MODE Step 1: Press to enter the main setup menu.
  • Page 36 PG10 Rev. B2, 8/16 Sensor Number (SENNUM): Sets the PG10’s sensor address number for the RS-485 Modbus communications. Options: 1 Stop bit, 2 Stop bits Setting the number of Stop Bits: MODE Step 1: Press to enter the main setup menu.
  • Page 37 PG10 Rev. B2, 8/16 Wiring the PG10 Battery Replacement: Step 1: Untwist the display locking ring (on the face of the gauge) counter- clockwise until the ring releases the display from the gauge. Step 2: Remove the front display to access the batteries.
  • Page 38: Wiring

    PG10 Rev. B2, 8/16 Wiring (continued) L1: 4-20 mA Circuit Process Gauge Controller Connector + EXCITATION +Vin – EXCITATION 4-20 mA CURRENT LOOP L1: 4-20 mA Circuit (C4 relay option shown) Process Gauge Controller Connector + EXCITATION +Vin – EXCITATION...
  • Page 39 PG10 Rev. B2, 8/16 Wiring (continued) L3: 0-5 V L3: 0-5 V (C4 relay option shown) Gauge Gauge Connector Connector SUPPLY SUPPLY VOLTAGE VOLTAGE GROUND +Vin +Vin Process Relay 1 Normally Closed GROUND Controller Process Relay 1 Normally Open Controller...
  • Page 40: Specifications

    PG10 Rev. B2, 8/16 Specifications: Overpressure: 2x full scale Burst Pressure: 4x full scale or 20,000 psig, whichever is less. Accuracy (linearity & hysteresis): +/-0.25% or +/- 0.1% B.F.S.L. Environmental: Housing: IP65 Compensated Temp: 20 to 130 F (-7 to 54...
  • Page 41 PG10 Rev. B2, 8/16 Output Specifications: 4-20 mA Output: Input Voltage (Excitation): 9 VDC min (no load) to 28 VDC max Input Current: 3-30 mA max Signal Variance: +/-0.16 mA at set points Output/Input: 2 wire loop powered Resolution: 14 bit...
  • Page 42 PG10 Rev. B2, 8/16 Notes Automation Products Group, Inc. Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 43 Rev. B2, 8/16 PG10 Notes Automation Products Group, Inc. Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com...
  • Page 44: Automation Products Group, Inc

    GROUP, INC. Automation Products Group, Inc. Tel: 1/888/525-7300 1/435/753-7300 Fax: 1/435/753-7490 e-mail: sales@apgsensors.com www.apgsensors.com Automation Products Group, Inc. 1025 W. 1700 N. Logan, UT 84321 To order additional copies of this manual, ask for APG document number 9003470 Rev. B2, 8/16...