NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal
injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a licensed professional immediately. Current
copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS.
OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS
PROPERTY DAMAGE.
READ
INSTALLATION & OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN
THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/
OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT
WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES,
FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
EXPLOSION OR RUPTURE HAZARD. THE
EXPANSION TANK MUST BE OPERATED SO
THAT THE PRESSURE DOES NOT EXCEED THE MAXIMUM
WORKING PRESSURE.
EXPLOSION OR RUPTURE HAZARD A relief
valve must be installed to prevent pressure in
excess of local code requirement or maximum working pressure
designated in the Product Manual, whichever is less. Do not expose
Product to freezing temperatures or temperatures in excess of 240° F.
Do not adjust the pre-charge or re-pressure this Product except for any
INSTALLATION & OPERATION INSTRUCTIONS
CAREFULLY
THE
PRODUCT
EXTROL
PRESSURIZED EXPANSION TANKS (ASME)
Models 200-L through 20000-L
adjustments required at the time of initial installation, especially if
Product corroded, damaged or with diminished integrity. Adjustments to
pre-charge must be done at ambient temperature only.
properly size the Product or follow these instructions may result in
excessive strain on the system lead to Product failure, serious or fatal
personal injury, leakage and/or property damage.
Potable Water Warning. This Product must not
be used in potable water or open systems of any
kind. These systems contain oxygenated water which will cause internal
corrosion and premature Product failure.
potable water systems.
Mount vertically only.
dead-end pipe.
This product can expose you to chemicals
including lead, which is known to the State of
California to cause cancer and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
L SERIES
®
Failure to
Use a Therm-X-Trol
Do not install on
for
®

Advertisement

loading

Summary of Contents for Amtrol EXTROL 20000-L

  • Page 1 Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing. THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS.
  • Page 2 Operating Instructions The AMTROL expansion tank may be placed in any convenient position 1. Check the expansion tank pre-charge before the system is filled with within the mechanical room (or building). If multiple tanks are installed, water.
  • Page 3 Suggested Piping Diagram AMTROL RETURN AIR ELIMINATOR AMTROL AIR SEPARATOR ISOLATION VALVE C.W.S. SUPPLY DRAIN AMTROL AUTOMATIC DRAIN FILL VALVE AMTROL EXTROL ® TRI-FLOW TANK VALVE SUCTION PUMP DIFFUSER Alternate Piping Diagrams ALTERNATE AIR SEPARATOR LOCATION RETURN AMTROL AIR ELIMINATOR...
  • Page 4 LOW-LEAD 1400 Division Road, West Warwick, RI USA 02893 T: 800.426.8765 www.amtrol.com © 2019 Worthington Industries Inc. Part #: 9017-094 (01/19) One or more features of this product are covered by U.S. patents, visit www.amtrol.com/patents for more information.

This manual is also suitable for:

Extrol 200-lExtrol l series