Accessories; Safety Information; Electrical Symbols; General Characteristics - UNI-T UT117C User Manual

High-precision true rms digital multimeter
Table of Contents

Advertisement

Optional magnetic hanging strap to enable performing measurement
without holding the multimeter by hand.
The current of conductor can be measured without changing or disconnecting
the circuit, by connecting current probe externally.
Drop proof: 2m
CAT III 600V
The user manual includes related safety information and warning prompt.
Please read the instructions carefully and strictly follow all warning and
precautions.
III. Accessories
Open the package to check the accessories shown below. Please contact
you supplier if any of them is founded missing or damage.
Standard accessories:
User manual ---------------------------------------------------- 1 pc
Test lead
--------------------------------------------------------
1.5V AAA battery
----------------------------------------------
Magnetic hanger
----------------------------------------------
UT-CS06A AC current probe (optional)
-------------------
IV. Safety Information
Please pay attention to "Warning labels and sentences". The warnings
identify the operation may pose danger to user and cause damage to the
multimeter or measured equipment.
The meter is in compliance with IEC/EN61010-1, 61010-2-033, Electromagnetic
Radiation EN61326-1 Safety Standard, Double Insulation Standard, Overvoltage
CAT III 600V, and Pollution Class 2. Failure to follow the operating instructions
may compromise or lose the protection provided by the multimeter.
Before use, please check the multimeter and test leads so as to prevent
any damage or abnormal case. Please stop use if any abnormal case
occurs, for example, test leads are exposed, casing is damaged, black
screen or abnormal display occurs, or others. It is forbidden to use without
cover closed in place, otherwise it may present a risk of electric shock.
In case of damaged test leads, please replace by test leads same with
model or electrical specification.
Do not make contact with exposed wire, connector, unused input terminal
or circuit during use.
Use cautious when working with voltage over DC/AC 30V, please grip the
test lead behind the finger guard to avoid electric shock.
Set the multimeter at maximum range if the measured range is unknown.
Do not apply overrated voltage or current between terminals, or between
any terminal and grounding.
Set the rotary switch to correct range. Disconnect test lead with measured
circuit before switching the functional switch. It is forbidden to switch over
during measurement, so as to avoid damage to the multimeter.
5
UT117C User Manual
1 pair
3 pcs
1 set
1 pc
UT117C User Manual
Before measuring on-line resistance, diode or continuity, please switch off
all powers of measured devices, and discharge all capacitors completely.
Before measuring current, please check if the fuse of the multimeter is good,
and switch off the measured current before connecting the multimeter
with circuit, to avoid a risk of electric spark.
Do not keep or use the multimeter in environments with high temperature,
high humidity, inflammable and explosive substance, and strong
electromagnetic fields.
Do not alter the internal wiring without authorization to avoid damage to
the multimeter.
When the symbol "
" shows on the LCD, please replace the battery
in time to ensure measurement accuracy.
Turn off the power in time after measurement. Remove the battery if the
multimeter is not used for a long time.
V. Electrical Symbols
Symbol
Description
Symbol
Do not place equipment and
its accessories in the trash.
Please dispose properly
according to the local regulation.
AC (Alternating Current)
DC (Direct Current)
Fuse
Bluetooth communication
Conform to European Union standards
Conform to UL STD 61010-1, 61010-2-032
Certified to CSA STD C22.2 NO. 61010-1, 61010-2-032
Applicable to test and measure the circuit connected with the
CAT Ⅲ
power distribution part of building's low-voltage MAINS installation.
Applicable to test and measure the circuit connected with the
CAT IV
power supply of building's low-voltage MAINS installation.
VI. General Characteristics
● Maximum voltage between signal input terminal and COM terminal: See
voltage input protection instruction for each range
● Designed with 10A input terminal: Fuse 11A/1000V (energy: 30KA)
Φ10.3×38mm
● Display count: 60000
● Display uprate rate: About 5 times per second
Description
Double insulated
Grounding
Warning
Low battery
UKCA certification mark
6