Thank you for purchasing this brand new multi-meter. In order to use this product safely and correctly, please
read this manual thoroughly, especially the Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close
to the meter, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year
from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse,
modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on
behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by
using this meter.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UT15B PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UNI-T UT15B PRO

  • Page 1 Preface Thank you for purchasing this brand new multi-meter. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the meter, for future reference.
  • Page 2: Table Of Contents

    UT15B PRO/UT17B PRO User Manual 1. Overview Table of contents UT15B PRO/UT17B PRO is highly reliable true RMS multimeter with auto backlight function. Equipped with its 1. Overview ---------------------------------------------------------- 4 10. Specification -------------------------------------- 20 built-in VFC anti-interference start mode, it can filter the carrier frequency interference from sine wave, various 2.
  • Page 3: Safety Instruction

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 3. Safety Instruction 9) Do not use the multimeter in extremely high-temperature or high-humidity environment, particularly in the damp environment in where the product performance may be severely degraded. 10) Do not change the internal circuit of the meter to avoid damage to the meter and user! 3.1 Safety Certifications...
  • Page 4: Electric Symbols

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 5. Comprehensive Specification 4. Electric Symbols 1) Maximum voltage between the input terminal and grounding: see the instruction about each input terminal protection voltage. Direct current A terminal: FF 11A H 1000V fast-acting fuse mA/μA terminals: FF 440mA H 1000V fast-acting fuse...
  • Page 5: External Structure

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 7. LCD Display (see Figure 2) 6. External Structure (see Figure 1) 1) Automatic backlight sensing window 2) LCD display 3) Function buttons Figure 2 4) Function selection knob 5) Measurement input terminal...
  • Page 6: Function Selection Knob And Buttons

    8.Function Selection Knob and Buttons MAX button (UT15B PRO): press to enter manual range mode and display the maximum value. To exit MAX /MIN measurement mode, press this button for over 2 seconds or switch the knob. (Only suitable for V...
  • Page 7: Measurement Operation Instruction

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 9. Measurement Operation Instruction 9.2 DC Voltage Measurement (See Figure 4) 1) Turn the function selection knob to the DC voltage scale. Check the built-in AA 1.5Vx2 batteries, the symbol will be displayed if the battery is low and needs to be 2) Insert the red test lead to V port and the black one to the replaced in time, which.
  • Page 8: Resistance And Circuit Continuity Measurement

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 9.3 Resistance and Circuit Continuity Measurement (See Figure 5a) Check the test leads for any loosing or other reasons in case there is a resistance no less than 0.5Ω when 1) Turn the function selection knob to the resistance scale.
  • Page 9: Capacitance Measurement

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 9.6 AC/DC Current Measurement (See Figure 7) 9.5 Capacitance Measurement (See Figure 6) 1) Turn the function selection knob to the A /μA scale. 1) Turn the function selection knob to the capacitance measurement 2) When the scale is A , insert the red test lead to the A port.
  • Page 10: Temperature Measurement (Only Ut17B Pro)

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual Buzzer: 9.8 Temperature Measurement (Only UT17B PRO) (See Figure 8) a. The buzzer will beep continuously when the input voltage is or over 1000V (AC/DC), which warns the range 1) Turn the function selection knob to °C/°F scale, and the is at the limit.
  • Page 11: Ac Voltage Measurement

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual Input impedance of mV range is ≥3GΩ, while others range are about 10MΩ. There will be unstable digital 10.3 Resistance Measurement display in case of mV range open-circuit; after connecting with the load, it can be controlled ≤ ±3 digits.
  • Page 12: Capacitance Measurement

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 10.6 Frequency/Duty ratio Measurement (Only UT17B PRO) 10.5 Capacitance Measurement Range Accuracy Resolution Range Accuracy Resolution 10Hz 100KHz ~ 0.01Hz 0.1KHz ~ ±(0.1%+3) 6.000nF Under REL mode: ±(4.0%+8) 0.001nF 1% 99.9% ~...
  • Page 13: Dc Current Measurement

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 9 AC Current Measurement Overload protection: 1000V-PTC Remark: configured point K-type (Ni-Cr ~ Ni-Si) thermocouple, which is only applicable for temperature Range Accuracy Resolution below 230°C/446°F 600.0μA 0.1μA µA 6000μA 1μA...
  • Page 14: Maintenance And Repair

    UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual 11. Maintenance and Repair Fuse replacement: The meter is unable to operate normally when the fuse is broken by voltage misdetection or overcurrent, so the fuse should be replaced in time.
  • Page 15 UT15B PRO/UT17B PRO User Manual UT15B PRO/UT17B PRO User Manual This manual is subject to change without prior notice.

This manual is also suitable for:

Ut17b pro