Siemens SITRANS LG260 Operating Instructions Manual page 61

Guided wave radar
Hide thumbs Also See for SITRANS LG260:
Table of Contents

Advertisement

Ʋ Cable: ø 6 mm (0.236 in), PA coated
Ʋ Cable: ø 6 mm (0.236 in)
Ʋ Cable: ø 11 mm (0.433 in), PA coated 20 Nm (14.75 lbf ft)
Ʋ Rod: ø 16 mm (0.63 in)
Torque for NPT cable glands and Conduit tubes
Ʋ Plastic housing
Ʋ Aluminium/Stainless steel housing
Input variable
Measured variable
Min. dielectric constant of the medium
Measurement accuracy (according to DIN EN 60770-1)
Process reference conditions according to DIN EN 61298-1
Ʋ Temperature
Ʋ Relative humidity
Ʋ Air pressure
Mounting, reference conditions
Ʋ Min. distance to internal installations
Ʋ Vessel
Ʋ Reflector
Ʋ Medium
Ʋ Mounting
Sensor parameter adjustment
PBD-51041061
8 Nm (5.9 lbf ft)
20 Nm (14.75 lbf ft)
20 Nm (14.75 lbf ft)
max. 10 Nm (7.376 lbf ft)
max. 50 Nm (36.88 lbf ft)
Level of solids
ε
≥ 1.5
r
+18 ... +30 °C (+64 ... +86 °F)
45 ... 75 %
+860 ... +1060 mbar/+86 ... +106 kPa
(+12.5 ... +15.4 psig)
> 500 mm (19.69 in)
metallic, ø 1 m (3.281 ft), centric mounting, process fit-
ting flush with the vessel ceiling
metallic, ø 1 m
Bulk solids - cereals, flour, cement (dielectric con-
stant ~2.0)
Probe end does not touch the vessel bottom
No gating out of false signals carried out
SITRANS LG260 - Operating Instructions
61

Advertisement

Table of Contents
loading

Table of Contents