Samsung SM-F711B Service Manual page 213

Hide thumbs Also See for SM-F711B:
Table of Contents

Advertisement

6-6. Sensor
6-6-6. Proximity/Light Sensor Problem
Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Image
Description
5. Check 'Capacitor' nearby 'U4013'
on the PBA as below.
- VDD_PROXY_LED_3P3=3.3V (Ref. C4075)
6. Check its 'Power Level' is OK
when it turned on.
- If not, replace U9004.
7. Check 'Sensor IC' 'U4013'
on the PBA as below.
- crack, open, short, etc.
8. If it has a problem, replace U4013.
9. Check 'Resistors' nearby 'U4013'
on the PBA as below.
- I2C signal
(Ref. R5055,R5057)
10. If it has no signal, replace PBA
11. If not, Exchange the PBA
with new one and check the device.