6-6. Sensor
6-6-3. Magnetic Sensor Problem
Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Image
Description
3. Check 'Capacitors' nearby '
on the PBA as below.
- VDD_SENSOR_1P8=1.8V
(Ref. C4068)
4. Check its 'Power Level' is OK
when it turned on.
- If not, replace PBA.
5. Check 'Sensor IC' 'U4010'
on the PBA as below.
- crack, open, short, etc.
6. If it has a problem, replace U4010.
7. Check 'Pads' nearby 'U4010'
on the PBA as below.
- I2C signal
(Ref. R5082,R5083)
8. If it has no signal, replace PBA
9. If not, Exchange the PBA
with new one and check the device.
CONFIDENTIAL
U4010
'