Download Print this page

Qlightec QLEX-SLM-650-EMG Quick Start Manual

Explosion proof emergency led light

Advertisement

Quick Links

Explosion proof Emergency LED Light
QLEX-SLM-650-EMG
20
60
Ex
66
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion-proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product's explosion proof grade and temperature grade.
4. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product are
fully understood.
5. Installation, maintenance and repair of the product must be performed by experts in the explosion proof field, or persons who have
received relevant training.
6. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
7. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
8. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
9. Please be careful of static electricity during product installation.
Please eliminate static electricity by using static eliminator or handle the product with anti-static globes.
10. Default condition of emergency backup battery switch is OFF("1") position. Please turn it ON and use the product when the product is
being wired.
11. In case of product abnormality, do not disassemble and contact our CS department.
When installing the product for the first time, do not disassemble the product arbitrarily except for disassembling and assembling the
terminal block cover for wiring the power line.
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to fire, electric shock, or product damage.)
- When the battery needs to be replaced, please contact our CS department.
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, fire, electric shock and loss of life.)
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Due to the nature of the product's surface, static electricity may be generated when it comes into contact with other objects. Use a
damp cloth or anti-static material to remove foreign substances on the outside of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Please scan the QR code for more
detailed product information.
www.qlight.com
1

Advertisement

loading

Summary of Contents for Qlightec QLEX-SLM-650-EMG

  • Page 1 Explosion proof Emergency LED Light QLEX-SLM-650-EMG Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Safety Precautions for Explosion Proof Products Please follow the instruction below to ensure safe and correct use of explosion proof products.
  • Page 2: Ordering Specifications

    110/230 [Model number] [Length] [Voltage] • QLEX-SLM • 650-650mm • 110/230-AC110V/230V Product Specifications ■ Explosion Proof Specifications Model number QLEX-SLM-650-EMG Zone 1 High risk gas/vapour Zone Range for operating definitions(Gas) Medium risk gas/vapour Zone 2 AC110V/230V voltage Acetone, Petrol, Methanol, Propane, Toluene...
  • Page 3: Grounding Instructions

    Dimensions (Units : mm) QLEX-SLM-650-EMG 2-Ø8 FITTING HOLES (685) Ø175 CABLE ENTRY 1/2'' NPT OR M20xP1.5 Grounding Instructions • Please use the M4 bolt to ground the product. • When connecting the grounding cable, please use a ring terminal (Inner diameter Ø5.2).
  • Page 4 Parts Definition/ Installation ■ Parts Definition Fixing bracket(STS) ④Lighting part Side cover(Al) ③Fixture ring PC tube(PC) ⑥Fixture ring loosening ⑦Fixture ring fastening ⑤Rotating arrow Bracket(STS) direction direction Upper cover(AI) Socket(Al) Housing(AI) SECTION A-A Terminal block(Al) ■ Installation • First, machine holes on the mounting surface ① . •...
  • Page 5 Technical Certification • Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality and technical innovations from leading institutions around the world. International Organization for International Explosion IECEx Standardization Qlight quality assurance systems have been manufactured and manage according to...
  • Page 6 MEMO...
  • Page 7 MEMO...
  • Page 8 RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805) www.qlight.com EN - QLEX-SLM-650-EMG - 2111A...