Parts Definition/ Installation
■ Parts Definition
Bracket(STS)
Upper cover(AI)
Housing(AI)
■ Installation
• First, machine holes on the mounting surface ① .
• The mounting hole of this product is 8mm in diameter.
• When machining taps, fasten the bolt through the mounting hole of the product.
• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
• Turn the fixture ring ③ in the loosening direction ⑥ .
• Grab the lighting part ④ and turn rotating arrow in both directions ⑤ to set the place where you want to illuminate.
• Fix the fixture ring ③ in the direction of ⑦ .
* Caution : Do not continuously rotate the lighting part ④ in one direction. It may cause disconnection of wiring on the lighting part.
Installation Environment and Protection Rating
• This product is designed to be explosion proof.
• Please make sure to use the product in an environment that meets the specified explosion proof rating and regulations.
• For further information, please visit our website (www.qlight.com).
Fixing bracket(STS)
④Lighting part
PC tube(PC)
⑤Rotating arrow
Socket(Al)
Terminal block(Al)
4
Side cover(Al)
⑥Fixture ring loosening
direction
SECTION A-A
③Fixture ring
⑦Fixture ring fastening
direction