Condensate Trap - Miele DA 424 V Operating And Installation Instructions

Cooker hood with extended canopy
Table of Contents

Advertisement

Connection for air extraction
Important:
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of condensation will need to
be addressed. The exhaust ducting will
need to be suitably insulated.

Condensate trap

(optional accessory)
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is installed to collect
and evaporate any condensate which
may occur. Condensate traps are
available for C 125 mm or C 150 mm
ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust connection. The arrow on the
housing indicates the direction of
air-flow.
30

Advertisement

Table of Contents
loading

Table of Contents