Ⅴ. Environment Specifications
Parameter
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Ⅵ. Reliability
No.
1
High temperature operating test
2
Low temperature operating test
3
High temperature storage test
4
Low temperature storage test
5
High humidity operating test
6
High humidity storage test
7
Thermal shock operation test
8
Thermal shock storage test
9
ESD
10
11
Model :IDS31-070W540DVA1E
Test Item
Contact
Air
Vibration
(Non-Operation)
Shock
(Non-Operation)
Rev. No : Ver. 0.90
Values
Units
Min.
Max.
0
+50
-20
+60
5
90
%RH
5
90
%RH
Conditions
Ta : 50℃, 120Hr
Ta : 0℃, 120Hr
Ta : 60℃, 120Hr
Ta : -20℃, 120Hr
Ta : 50℃, 80%RH, 120Hr
Ta : 50℃, 90%RH, 120Hr
Ta : 0℃, 60min  0℃~50℃, 30min
 50℃, 60min, 50Cycle
Ta : -20℃, 60min  -20℃~60℃, 30min
 60℃, 60min, 50Cycle
8KV,1sec/cycle
15KV,1sec/cycle
Linear sweep 30minutes, 10~200Hz
1.5G, X, Y, Z direction
50G, 20ms, Half-sine wave
±X, ±Y, ±Z
Date :15/APR/2015
Preliminary
Notes
Page
of 22