Checking The Hydraulic Fluid And Engine Oil - Toro 30435 Operator's Manual

Table of Contents

Advertisement

Important
Do not overfill the battery because
electrolyte (sulfuric acid) can cause severe corrosion and
damage to the chassis.
5. Wait five to ten minutes after filling the battery cells.
Add electrolyte, if necessary, until the electrolyte level
is up to the "UPPER" line (Fig. 35) on the battery
case.
6. Reinstall battery filler caps.
2
3
1
Figure 8
1. Filler caps
2. UPPER line
Warning
Charging battery produces gasses that can
explode and cause serious injury.
Keep cigarettes, sparks and flames away from
battery.
Make sure the ignition switch is off.
Ventilate when charging or using battery in an
enclosed space.
7. Make sure the vent caps are installed in the battery.
Charge the battery for 1 hour at 25 to 30 amps or 6
hours at 4 to 6 amps. Do not overcharge the battery.
8. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the charger
leads from the battery posts (Fig. 9).
m-5004
3. LOWER line
19
4
2
Figure 9
1. Positive Battery Post
2. Negative Battery Post
9. Install the battery in the machine and connect the
battery cables. Refer to Installing Battery on page 34.
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
8
St e p
No parts needed for this step.
Checking the Hydraulic Fluid
and Engine Oil
Check the hydraulic fluid level before the engine is first
started.
Refer to Checking the Hydraulic Fluid on page 38.
Check the engine oil level before the engine is first
started.
Refer to Checking the Engine Oil Level on page 31.
3
1
m-4970
3. Red (+) Charger Lead
4. Black (–) Charger Lead

Advertisement