Napoleon ROGUE RSE625RSIB User Manual page 41

Hide thumbs Also See for ROGUE RSE625RSIB:
Table of Contents

Advertisement

Available languages

Available languages

Leak Testing Instructions
!
WARNING!
part of the gas system is replaced.
WARNING!
!
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See
Leak Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve
on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
STOP
gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
N415-0567CE-GB-DE Mar 25.20
A leak test must be performed annually and each time a cylinder is hooked up or if a
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
41
www.napoleon.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rogue rse525rsib

Table of Contents