LG LFXS24553S Service Manual page 83

Table of Contents

Advertisement

To reduce noise level, the piston stroke is slowly increased to full power during start up.
There are 6 protection logics designed to protect the linear compressor system. When a failure is detected,
the compressor will shut and will try to restart after a set period of time for each type of failure. The LED
located on the inverter drive PCB will flash the appropriate code to indicate the detected failure. This code will
continue to flash until the unit is disconnected from the power source.
Inverter Error Codes
Inverter Error
Codes
FCT0
Stroke
No Connect
Lock
Current
IPM
Communication
Error
code
5
|Vm, Im|> 2.5V+20% @ COMP off
10
|Stroke|>17.5mm
15
|Stroke|<=9.4mm &
While 4 seconds |AC Current|<0.05A
25
|AC Current|>1.0A & |Stroke|<3.0mm
30
35
uc_Fo_Trip!= 0
-
Checksum error
Step 1) Start up - Half stroke interval for first 30
seconds.
Step 2) Ramp up - Stroke increases every 0.8sec until
maximum stroke length is reached (about 3
min, 15 sec)
Step 3) CVCF interval - 180V / 60Hz
Step 1) Start up - Half stroke interval for first 20
seconds.
Step 2) Ramp up - Stroke increases until maximum
stroke length is reached (about 1 min, 40 sec)
Step 3) VVCF interval - target voltage and frequency
controlled by Control Board signals
Requirement
|Current|>3Ap
Off Time
The number
of LED
flashes
30s
1
60s
2
40s
3
150s
5
360s
6
20S
7
0
8