Mounting

1 Determine the points for the bolt holes
(determined according to the specifica-
tion of the instrument you have chosen)
Drill two holes of appropriate depth in
the wall using a drill bit that fits the bolts,
install the mounting bracket, and then
hang the electric water heater
2 Attach the power outlet to the wall
The socket requirements are as follows:
220 – 240V / 10A,
single-phase,
wire It is recommended to place the sock-
et on the left side above the water heater
Attention!
Please use the accessories provided by the
manufacturer to install the water heater
The electric water heater must not be
mounted on the wall before you make
sure that the bracket is securely and firmly
installed Otherwise, the electric water
heater may fall off the wall, resulting in
damage and even serious injury or injury
When determining the points for holes
for anchor bolts, a free space between the
bottom of the water heater and the floor
should be at least 0 6 m
Attention!
The water pressure in the water heater cor-
responds to the water pressure in the wa-
ter main If the pressure in the line exceeds
0 7 MPa, then a pressure reducer should
be installed in front of the water heater so
that the pressure does not exceed 0 7 MPa
Attention!
In places or on a wall where water can en-
ter, the installation height of the electrical
outlet must be at least 1 8 m
10
Water supply connection
1 The water heater is connected to a water
supply network with a pressure of at least
0 1 MPa, maximum 0 7 MPa
2 To connect the water heater to the water
supply, pipes with a diameter of G1/2 are
used
3 When connecting pipes, use rubber seals
on the threaded pipe ends to prevent
leakage
three-
4 Screw the safety valve onto the inlet pipe,
marked in blue and with a sign of the di-
rection of water flow, so that the water
flow matches the direction of the arrow
on the valve body On the pressure relief
hole of the safety valve, put a drain pipe
to drain water (it may appear when heat-
ed) into the sewer
5 The safety valve is installed on the cold
water pipe (marked with a blue ring)
(maximum pressure 0 7 MPa / 7 Bar) If
the water pressure in the line exceeds
7 Bar, a pressure reducing valve should be
installed
6 Connect the water heater with the valve
mounted to the water supply network —
install a shut-off valve at the water supply
point
7 Connect the desired number of consump-
tion points to the outlet marked in red
8 Open the shut-off valve and one of the
collapsible valves. After filling the tank, as
evidenced by the outflow of water from
the collapsible tap, close the collapsible
tap and check the tightness of all connec-
tions
Electrical connection
1 Before connecting, make sure that the
power supply at the connection point
matches the parameters indicated on the
identification plate with the technical
data of the device The water heater is de-
signed to be connected to a single-phase
220 – 240 V electrical network When
installing the water heater, the current
electrical safety regulations must be ob-
served
2 The electrical outlet and plug must be
kept dry at all times to prevent electrical
leakage Regularly check that the electri-
cal plug is firmly connected to the outlet.
The electrical socket must be designed for
a rated current of at least 10 A, an elec-
trical cable with a core cross section of at
least 3 × 1.5  mm
(for copper) Carry out
2
the check in the following order: insert
the electric plug into the socket, after half
an hour of operation, turn off the water
heater and remove the plug from the
socket, check with your hand if the plug
has warmed up If the plug has become
hotter than 50 °C, replace the outlet with
a different one to avoid damage, acci-
dents, or fire due to poor electrical con-
tact This should be done by a specialist
Attention!
1 Do not mount additional devices, such as
a shut-off valve, between the safety valve
and the inlet pipe
2 If the water at the installation site con-
tains a large amount of calcium, manga-
nese or iron salts, then it is necessary to
install an appropriate filter in the supply
system to reduce the amount of scale in
the tank and on the heating element
3 Before connecting the storage water
heater, make sure that the water heater is
properly grounded Proper grounding is
important to minimize electric shock and
fire hazards. The power cord is equipped
with a plug with a grounding contact
The device must be used with a properly
grounded power outlet If the outlet you
plan to use is not properly grounded or
protected by a time delay fuse or circuit
breaker, contact a qualified electrician to
install the correct outlet
4 To ensure reliable operation and safe op-
eration of the water heater, before using
it for the first time, check that it is correct-
ly connected to an AC 220 V electrical net-
work The connected water heater must
be securely connected to the ground
loop of your electrical network Using
the water heater without grounding is
life-threatening.