D. M
M
AST
OUNTING
The final installation step involves mounting your SkyWay 7000 radio to an
outdoor mast.
Slide the U-bolt around the mast, through the stepped bracket, and then
1.
through the L-bracket.
Insert 3/8" flat washers on to the ends of the U-bolt.
2.
Thread two 3/8" nylock nuts on to U-bolt ends.
3.
For azimuth antenna adjustment, loosen the inner U-bolt nut and rotate radio
4.
around mast.
For elevation adjustments, loosen the outer U-bolt nut and adjust radio so that
5.
the U-bolt leg slides along L-bracket slot.
Wrench tighten both nuts following antenna alignment.
6.

10. Spectrum Analysis

Your SkyWay unit comes with embedded spectrum analysis tool to facilitate
your site survey (NOTE: This feature is available on software version 2.0 or
higher). Spectrum analysis provides valuable information about the RF
congestion in the local area and allows the selection of the ideal channel.
Prior to enabling a spectrum analysis, ensure that the units are mounted at the
desired location and align the antenna in the general direction of the peer radio
before beginning the analysis.
Note: Do not turn on the remote unit during the spectrum analysis, as the
presence of the remote unit will severely distort the sweep data.
Navigate to the Installation -> Spectrum Analysis menu to access the
Spectrum Analysis screen:
To start the spectrum analysis, click Start button. The unit will scan through
the available channels and display the results on the bottom half of the screen.
Numerical results will indicate the interference levels based on received signals
13