Connection Procedure; Access Point Mode; Client Mode - Danfoss OPX Series User Manual

Wireless control panel
Table of Contents

Advertisement

3.

Connection Procedure

Default operation mode is Off but can be configured for Access Point Mode or Client Mode
operation from parameter xx-xx-yy WiFi Operation Mode.
xx-xx-yy
3.1

Access Point Mode

The wireless SSID is Danfoss following the serial number of the iC7 Product. For example,
Danfoss-012345678900 is the default wireless SSID for a product with the serial number
012345678900. The serial number can be located on the product label or alternatively from
parameter xx-xx-0x Serial Number. Default Password is Danfoss1234
xx-xx-0x
• Open the MyDrive Insight app and establish the Wi-Fi connection, see table for descriptions
of the white Wi-Fi LED.
• When prompted, change the default password due to security restrictions. The password
must be at least 8 and maximum 48 characters.
If the password is not changed, it leaves only 10 minutes for connecting and performing operations.
After this, the wireless connection closes.
Reset password
If password is forgotten, it can be reset from MyDrive Insight through the NFC interface on the
control- or wireless panel or through the Service Port.
3.2

Client mode

xx-xx-1x
xx-xx-1y
• Open the MyDrive Insight app and establish connection either wired or wireless.
• Configure the Client Mode SSID and Password according to the access point
• Configure Wi-Fi Operation Mode to Client Mode operation
WiFi Operation Mode
AP Wireless SSID
CM Wireless SSID
CM Password
Classified as Business
Access_Point_Mode
Client_Mode
Off
Danfoss-012345678900
Danfoss-123456789
123456789