6
Maintenance
6.1
Prepare maintenance
NOTICE
Disconnect system from energy sources!
Ensure that the electrical equipment is discon-
nected from the power supply during the work.
Ensure that there is no wastewater in the system.
Push the lock to the side (on both sides).
Remove the cover.
Remove the pump
Open the quick-release closure.
Remove the pump.
Clean the float switch (remove dirt from the floater and
housing if necessary)
To do so, pull the floater off the float body if necessary.
34 / 116
016-307