10-2-14 DC_link voltage sensor error
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the reactor wire connected?
3) Is the DC_link capacitor("A") assembled in accordance the specification? (Outdoor PBA)
4) Is the DC_link resistor("B") value is normal? (Outdoor PBA)
2. Troubleshooting procedure
Is the connected of reactor wire?
Restart after power off.
Start the operation (cooling mode or heating mode)
voltage ("A") is normal in operation mode?
Normal range(280Vdc~320Vdc)
sensing voltage("B") is normal in operation mode?
Normal range (0.2Vdc~4.8Vdc)
Is the reactor insulation damaged?
Exchange the Reactor
10-16
LED3
LED OFF
(PBA-Reactor)
YES
Is the DC_link
YES
Is the DC_link
YES
YES
7-SEG DISPLAY
E469
DC_link voltage sensor error
M
O
D
L E
DB92-02866A
CE101,CE102,CE103
DB92-02867A
CE053,CE054,CE055,CE056
NO
Connect the reactor wire
NO
Check the power input
NO
Exchange the Outdoor PBA
NO
Exchange the Outdoor PBA